appLianCe COnTrOL uniT - reMOvaL

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. To remove the Appliance control unit, open
the control panel (See page 4-18).
2. Press the locking tab and disconnect the
wire harness connections to the ACU
(See page 4-23).
3. To remove the water level pressure hose,
use a pair of needle nose pliers to squeeze
the clamp and move it down the hose.
Hose
Clamp
4. Pull the hose off the connection with a slight
twisting motion.
5. Remove one T-20 screw securing the ACU
board to the control panel bracket.
One T-20
Screw
6. Pull the board forward, away from the
control panel bracket, and slide it to the left
to remove the tab from the slot at the other
end of the board.
7. Lift the locking tab and disconnect the door
lock wire harness connector.
8. Remove the board from the control panel.