FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY
Be sure to perform the Diagnostic Tests before replacing the
system components.
Pump Motor Continuity Test
Pins
1 to 2
Motor Continuity Test
1. Unplug washer or disconnect power.
2. Disconnect the wire harness from the motor and measure the
resistance of the motor. Use the following table:
Pins
1 to 2
2 to 3
1 to 3
Transformer Connector
Primary (Black to black) 220 ohms
White to white 3 ohms
Green to green 1.2 ohms
Water Temperature Sensor
1. Unplug washer or disconnect power.
2. Disconnect the wire harness from the water temperature sensor
and measure the resistance of the sensor. Use the following table.
An abnormal condition is an open circuit. This reading can be
taken from the cable attached to the CCU terminal TH2.
Temperature
32°F (0°C)
86°F (30°C)
104°F (40°C)
122°F (50°C)
140°F (60°C)
158°F (71°C)
203°F (96°C)
Cycle Temperature Selections
Cycle
WHITES . . . . . . . . . . . . . . . . . . . . .Hot = 116.6°F (47°C)
COLORS . . . . . . . . . . . . . . . . . . .Warm = 95°F (35°C)
BRIGHTS . . . . . . . . . . . . . . . . . . . .Cold = Tap Temp.
PERM. PRESS . . . . . . . . . . . . . . . . .Warm = 95°F (35°C)
DELICATES AND KNITS . . . . . . . . . . . . .Warm = 95°F (35°C)
QUICK CYCLE . . . . . . . . . . . . . . . . .Warm = 95°F (35°C)
PART NO. W10340707A
Results
Normal = approx. 106
Abnormal = Infinity
Results
Normal = approx. 6.45
Abnormal = Infinity
Results
35.9 k
9.7 k
6.6 k
4.6 k
3.2 k
2.3 k
1 k
Wash Temp. (all rinses are COLD)
Water Valve Locations
CCU Wire Harness Connector Table
Unplug washer or disconnect power before taking ohm measurements.
Terminal
Component
RP2
Wax Motor
DLS2
Door Locked Switch Continuity:
Locked/Unlocked
DL3
Door Lock Coil
Locked or Unlocked
SET2
Temperature
Sensor
DP2
Drain Pump
DCS3
Door Switch
DI6
Hot Inlet Valve #1
VCH7
Cold Inlet Valve #2
Cold Inlet Valve #3
IF2
RFI/UIC Transformer
PS8
Pressure Switch
**The number 1 pin has been marked on the bottom part of the connector.
**An infinity measurement occurs when the multimeter does not detect an ohm reading.
Manually Unlocking the Door Lock System
1. Unplug washer or disconnect power.
2. Remove the toe kick panel.
3. Reach up along the inside of the front and locate the bottom
of the latch assembly.
4. At the bottom of the latch assembly is a tear-drop shaped tab.
5. Gently pull the tab down about 6 mm (1/4") or until a click is heard.
ELECTRONIC ASSEMBLIES -
REMOVAL OR REPLACEMENT
IMPORTANT: Electrostatic (static electricity) discharge may cause
damage to electronic control assemblies. See page 1 for details.
NOTE: Be sure to perform the Diagnostic Tests before replacing the
control board.
PAGE 14
Hot Inlet
Cold Inlet
Valve #1
Valve #2
H
( ) Ohm
Abnormal
Pin
Value
Value
Connectors* Coding
1.2k
Infinity**
1, 2
at 25°C
1, 2
door locked.
No Continuity:
door unlocked.
750
Infinity** 1, 3 door lock
3, 5 door unlock
Varies with
Infinity**
1, 3
temperature
changes.
See above.
106
Infinity**
1, 3
Continuity
1, 2
at door close.
No continuity
at door open.
3.55k
Infinity**
1, 3 (hot
valve #1)
3.55k ,
Infinity**
1, 3 (cold
either coil (or more than valve #2)
10% lower
5, 7 (cold
or higher)
valve #3)
0
Infinity**
1, 2
(or more than
10% lower
or higher)
Infinity** for all Continuity at any
1, 2
except 4, 6 switch except
3, 4
with no water 4, 6 with no
4, 5
in tub
water in tub
4, 6
Cold Inlet
Valve #3
Wire
1
1
1
1
1
1