Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. To access the heating elements, remove
the front panel (See page 4-32).
2. Remove two Phillips head screws securing
the access panel at the bottom of the
ornament panel.
Two Phillips
3. Support the panel when removing the
second screw.
HeaTinG eLeMenTS
Screws
4. Remove the access panel. There are three
slots for heating elements for electric water
heat in this washer.
5. The back end of the heating elements are
supported by three brackets in the outer tub,
visible here with the basket removed.
4-34
Three Slots
Three
Brackets