Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. To remove the lower back panel, remove
the back panel (See page 4-36).
2. Loosen two T-30 screws at the bottom of
the panel, attached to the base of washer.
3. Remove two T-20 screws securing the
drain-T to the lower back panel.
4. Remove four T-30 screws, two on each
side, securing the lower back panel to the
side panels.
Two T-20
Screws
Four T-30

LOWer BaCK paneL

Two T-30
Screws
Screws
5. Lift the panel up from the bottom and move
it back away from washer to remove panel.