Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. To remove the coin drop, open the control
panel (See page 4-18).
2. Press the locking tab and disconnect the
coin drop from the coin one connector.
3. Cut the wire tie securing the coin drop
wire harness in the control panel. Make
sure to replace any cut wire ties during
reinstallation.
Coin Drop
Connector
COin DrOp
4. Remove four 7/32" hex nuts securing the
coin drop to the control panel.
5. There is a nut, star washer and flat washer.
It may be easier to use a magnet to remove
the washers.
6. Push the coin drop out the front of the
control panel to remove it.
Wire Tie
7. There is a card reader connector near the
coin drop connectors.
4-20
Card Reader
Connector
Coin Drop
Connector