Technical data

3.1
Pumps
Information / pump type
Weight
*)
Power P1 / P2
Speed
Operating voltage
Rated current
**)
Max. pumping capacity
Max. pumping height
Max. temperature of pumped
medium (continuous)
Protection rating
Protection class
Connection type
Connecting cable (10 m)
required fusing
Operating mode
*) Version for S1 operation. 2 kg heavier for S3 operation.
**) Per pump, Duo systems have 2 pumps with identical technical data.
Pumping capacity and height (SPF pumps)
(1)
(2)
(3)
(4)
3.2
Dimensions
Height
Outer diameter [mm]
Please note the documentation enclosed with the control unit for details of the technical specifications and ambient condi-
tions of the control unit.
26 / 116
1400
24 kg
1.6 kW / 1.1 kW
1370 rpm
230 V; 50 Hz
7.3 A
38 m³/h
7 m
Plug
SPF 1400
SPF 1500
SPF 3000
SPF 4500
See instructions for engineering chamber LW 1000 (part. no. 010-701)
Backwater lifting station / Installation and operating instructions
SPF
1500
3000
24 kg
25 kg
1.4 kW / 1.1 kW
3.2 kW / 2.7 kW
1415 rpm
2845 rpm
400 V; 50 Hz
2.7 A
5.4 A
40 m³/h
47 m³/h
8 m
16 m
40 °C
IP68 (3 m WC)
I
Direct connection
7 x 1.5 mm²
See control unit operating instructions
S1 / S3 - 50%
1200
4500
26 kg
4.5 kW / 3.7 kW
2845 rpm
7.5 A
55 m³/h
20 m
010-694

Advertisement

Table of Contents
loading

Table of Contents