Topcon GTS-600 Series Instruction Manual page 111

Table of Contents

Advertisement

7
Collimate target A.
8
Press [F6](SET)key.
Repeat the procedures in step
that the count of measured times matches to
the one in FACE(1).
* 2),3),4)
The title display will be shown automatically.
9
Collimate target B (more than ±10° from the
level ) in reverse telescope setting (FACE(2)).
*5)
10
Press [F6](SET)key. *1)
11
Turn the telescope in normal telescope
setting(FACE(1)).
12
Collimate target B.
13
Press [F6](SET) key. Repeat the procedures
12
13
in step
and
so that the count of
measured times matches to the one in
FACE(2).
Then the display returns to main menu.
*1) It is able to get the average value from 1 to 10 measurements. To get the average, repeat the
4
procedures in steps
*2) The compensation values of 1) Error of vertical axis (X,Y tilt sensor offset),
2) Collimation error, and 3) Error of vertical angle 0datum will be set and memorized internally.
*3) The operating procedure steps to set compensation value of 4) Error of horizontal axis.
*4) Pressing [F1](SKIP) key enables to set next step without changing the last compensated value.
*5) Pressing [F1](SKIP) key makes end of setting without changing compensation value.
7
8
and
so
5
9
10
,
or
,
. The measured times is counted in the second line of display.
Collimate
A
(Reverse)
[F6]
LEVEL±0
V:270°04'20"
SKIP
(B)HORIZONTAL Axis
LEVEL±10°
V:270°04'20"
SKIP
Collimate
B
(Reverse)
[F6]
LEVEL±10°
V:270°04'20"
SKIP
Turn
telescope
LEVEL±10°
V: 69°58'30"
SKIP
Collimate
B
(Normal)
[F6]
8-10
8 CHECK AND ADJUSTMENT
FACE 2
5/5
SET
FACE 2
/0
SET
FACE 2
/5
SET
FACE 1
5/5
SET
Complete