3.2.4 Distance Measurement (Single/N-times Measurement)

When presetting the number of times, the instrument measures the distance as the setting times and
the average distance will be displayed.
When presetting the number of times as 1, it does not display the average distance, because of single
measurement. It has been set at single measurement at factory.
1)Setting the number of times
Confirm the angle measurement mode.
Operating procedure
1
Press [F1](SD) or [F2](HD) key.
2
Press [F6](
) key to get the function page as
2.
3
Press [F3](MEAN) key.
4
Input the setting the number of times, and
press [ENT] key. *1)
[Example] 4 times
N-times measurement starts.
2)Measuring Method
Confirm the angle measurement mode.
Operating procedure
1
Collimate the center of the prism.
2
Select the measurement mode by pressing
[F1](SD) or [F2](HD) key.
Example:Horizontal distance
N-times measurement starts.
3 STANDARD MEASUREMENT MODE
Operation
V :
90°10'20"
HR: 120°30'40"
SD
HD
[F2]
V :
90°10'20"
HR: 120°30'40"
HD:
VD:
MEAS
MODE
[F6]
REC
SO
[F3]
Average times
N:0
EXIT
[F4][ENT]
V :
90°10'20"
HR: 120°30'40"
HD:
VD:
REC
SO
Operation
Collimate
V :
90°10'20"
HR: 120°30'40"
SD
HD
V :
90°10'20"
[F2]
HR: 120°30'40"
HD:
VD:
MEAS
MODE
3-5
Display
NEZ
0SET
HOLD P1
PSM
0.0
PPM
0.0
(m)
F.R
VH
SD
NEZ
P1
MEAN
m/ft
P2
BS
PSM
0.0
<
PPM
0.0
(m) *F.N
MEAN
m/ft
P2
Display
NEZ
0SET
HOLD P1
PSM
0.0
PPM
0.0
(m)
F.N
VH
SD
NEZ
P1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents