Topcon GM-55 Total Station Setup Using Topcon FC-5000 Data Collector
Maryland NRCS

1. Set up tripod and level base plate.

2. Place GM-55 Total Station unit on tripod and level:

a. Adjust tripod legs individually to get the bubble near level.
b. Use thumb screws on total station to make fine adjustments and center level bubble.
c. Rotate total station and center over each tripod leg. Verify that the bubble is level at each
stop. Make fine adjustments as necessary.

3. Press the power button on the total station.

a. Make fine level adjustments to center digital level bubble.
b. Push [F1] to select "OK".
4. Aim total station sight towards North and establish 0° (deg).
a. Rotate total station so that it aims in the direction of magnetic North.
b. Push [F1] to select "0Set" function.
5. On the FC-5000 data collector, press the power button
6. Once at the Windows 10 home screen, open the MAGNET Field
a. Tap the Windows icon
b. Tap All Apps icon
c. Scroll down to M section and tap MAGNET Field folder.
d. Tap and open MAGNET Field app.
****** If this is a first-time set up, proceed to step 7. If this FC-5000 has been set up previously, skip
to step 11. ****************************************************************************************************
7. Close the Connections window by pressing the home screen icon

8. Set up GM-55 connection profile.

a. Tap Configure icon.
b. Tap Survey icon.
c. Under the Optical Configuration box, tap [Edit].
d. Under the Configuration window, enter the following before tapping [Next >>]:
Name: GM-55 TS
Type: Conventional
e. Under the Config: Instrument window, enter the following before tapping [Next >>]:
Manufacturer: Topcon
Model: GM-50/100(Topbasic)
f.
Under the Config: Conn Mode window, enter the following before tapping [Next >>]:
Initial TS Connection: Bluetooth TS
g. Under the Config: Survey Settings window, enter the following before tapping [Next >>]:
Meas Method: Direct
Tolerances, Hz: 5.000
Tolerances, Dist.: 0.02
Tolerances, VA: 5.000
Ver 1.1, 30 August 2018
at the bottom-left of the tablet screen.
.
.
©
software.
near the top-right.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GM-55 and is the answer not in the manual?

Questions and answers

Summary of Contents for Topcon GM-55

  • Page 1 Topcon GM-55 Total Station Setup Using Topcon FC-5000 Data Collector Maryland NRCS 1. Set up tripod and level base plate. 2. Place GM-55 Total Station unit on tripod and level: a. Adjust tripod legs individually to get the bubble near level.
  • Page 2 h. Under the Config: Survey Settings window, enter the following before tapping the checkmark icon near the top-right: Measurement Type: HA/VA/SD Target Type: Prism EDM Mode: Coarse g. Tap the accept/home screen icon near the top-right. 9. Establish default measurement units: a.
  • Page 3 11. Connect the FC-5000 data collector to the GM-55 Total Station: a. Tap Connect icon. b. Under the Connections window: Tap Optical radio button. Select GM-55 TS configuration. Select/check: Connect to last used BT device Select/check: Prompt for connection at startup Tap [Connect].
  • Page 4 Tap the menu icon. Tap and select: Get from Instr Verify that the listed reading matches the “HR:” angle reading on the GM-55 display. Tap Set icon. e. Tap Yes to store the measured backsight point. In the Store Point As… window, enter the following before tapping the checkmark icon near the top-right: Point: 10 ****** Use prefered numbering rule but do not go above point number 99.
  • Page 5 16. Proceed to collect general survey data points: a. Tap Survey icon. b. Tap Topo icon. c. Under the Sideshot-Direct: Normal window, enter the following data: Point: 100 ****** Survey shots should stay within point range: 100 – 2999. ****** Code: <user-defined;...
  • Page 6 20. Press and briefly hold the power button on both the FC-5000 data collector and GM-55 total station to shut-down each device. Disassemble and pack up equipment. Be sure to center the levelling pegs (heightwise) on the GM-55 and keep the rotation-lock knobs loose during storage.

Table of Contents

Save PDF