PSR-VU-9537-UBWEB-GUI SETUP INTRODUCTION

The Web-GUI allows the user to communicate with the repeater locally. To connect to the repeater locally, you
will need a laptop with an Ethernet port and an RJ-45 crossover cable.
NOTICE TO USERS, INSTALLERS, AUTHORITIES HAVING JURISDICTION, AND OTHER INVOLVED PARTIES
This product incorporates field-programmable software. In order for the product to comply with the requirements in the
Standard for in-building 2-Way Emergency Radio Communication Enhancement Systems, UL 2524 certain programming
features or options must be limited to specific values or not used at all as indicated below.
Program feature or option
Remote Power Switch
Battery Not Charge Check
Battery Check
Donor Antenna Malfunction
Check Time
Please note that some selections of the Donor Antenna Malfunction Check Time setting could impact the
compliance of the UL 2524 code. The selections available for this option are 0sec, 10sec, 45sec, 90sec, 3min,
6min, 15min, 30min, 1hour, 2hour, 4hour, 8hour, 12hour, 24hour, and 48hour. Selection of 24 hours or less will
be required to remain compliant with UL 2524.
Advanced RF Technologies, Inc.
Permitted in UL 2524?
(Y/N)
N
Y
Y
Y
Figure 7-1
Donor Antenna Malfunction Check Time
Possible settings
Enable/Disable
On/Off
Check All/Except
Installed/Check Off
0sec, 10sec, 45sec, 90sec,
3min, 6min, 15min, 30min,
1hour, 2hour, 4hour, 8hour,
12hour, 24hour, and 48hour
35
Settings permitted in
UL 2524
Disable
On
Check All
0sec,
10sec,
45sec,
90sec,
3min,
6min,
15min, 30min, 1hour,
2hour, 4hour, 8hour,
12hour, and 24hour