Grounding; Figure 3-8 Ground Cable Terminal - ADRF PSR-VU-9537-UB Manual

Table of Contents

Advertisement

(WARNING: The circuit breaker switch on the ADRF-BBS/BBL-24 must be set to OFF before connecting it to
the PSR-VU-9537-UBto prevent damage to the repeater or the ADRF-BBS/BBL-24 and personal injury.)
Note: Please contact ADRF Technical Support for assistance if you are unfamiliar with the installation procedure
of the battery box.

3.2.6 Grounding

The grounding terminal is located at the lower right-hand side of the BDA. A grounding cable should be properly
connected before powering on the equipment.
Figure 3-8
Ground Cable Terminal
Ground terminals located on the side of the repeater and can support a ground cable up to 1.25mm² (16AWG)
in diameter and should be permanently connected to a grounding bar.
Advanced RF Technologies, Inc.
23