Page 1
Epoch-III-P8024/8030/8037NM ANUAL Version 1.6 2607 Colorado Blvd. Los Angeles, CA 90041 Tel: 323-254-8131 Fax: 323-254-4928 www.adrftech.com...
Page 2
The following is a list of abbreviations and terms used throughout this document. Abbreviation/Term Definition Automatic Gain Control Automatic Level Control AROMS ADRF’s Repeater Operation and Management System Base Transceiver Station CDMA Code Division Multiple Access Continuous Wave (un-modulated signal) Distributed Antenna System...
Page 3
Epoch-III-P8024/8030/8037NM User Manual V1.6 Version 1.6 (Released March 31, 2008) Information in this document is subject to change without notice. Advanced RF Technologies, Inc. 1996-2008. All rights reserved. Please send comments to: E-Mail: info@adrftech.com Phone: (323) 254-8131 (800) 313-9345 Fax:...
User Manual V1.6 1. Epoch-III-P8024/8030/8037NM 1.1 Introduction Epoch-III-P8024/8030/8037NM is a CDMA 1900 MHz RF repeater which enhances in-building wireless coverage in the most effective and cost efficient way. For its intelligent design and versatility, the Epoch-III-P8024/8030/ 8037NM is the ideal choice for wireless coverage problems indoors. Epoch-III-...
Epoch-III-P8024/8030/8037NM User Manual V1.6 1.2 Warnings and Hazards WARNING! ELECTRIC SHOCK Opening the Epoch-III-P8024/8030/8037NM could result in electric shock and may cause severe injury. WARNING! EXPOSURE TO RF Working with the repeater while in operation, may expose the technician to RF electromagnetic fields that exceed FCC rules for human exposure.
Page 10
Epoch-III-P8024/8030/8037NM User Manual V1.6 WARRANTY Opening or tampering the Epoch-III-P8024/8030/8037NM will void all warranties. Lithium Battery : CAUTION. RISK OF EXPLOSION IF BATTERY IS REPLACED BY INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO INSTRUCTIONS. Ethernet Instructions : This equipment is for indoor use only. All cabling should be limited to inside the building.
In this case, the Epoch-III-P8024/8030/8037NM works as a remote unit sending its information to the collocated external modem box. Note: ADRF’s Web GUI has not been developed for Microsoft Internet Explorer and other web browsers (e.g. Netscape, FireFox, Mozilla, etc.) may not be compatible. ADRF’s Web GUI has not been tested with Microsoft Internet Explorer versions higher than 6.0.
Epoch-III-P8024/8030/8037NM User Manual V1.6 2.2 Switches & Indicators 2.2.1 LEDs Epoch-III-P8024/8030/8037NM has three LEDs on the front panel of the repeater as shown below in Figure 4. Figure 4 – Epoch-III-P8024/8030/8037NM Repeater LED View POWER If the LED is lit GREEN, it indicates that there is AC power to the repeater.
Epoch-III-P8024/8030/8037NM User Manual V1.6 2.2.2 AC Power Switch & DC Power Port for External Modem Box The AC Power on/off switch is located on the bottom of repeater (Figure 5). The switch should be powered on after the repeater has been installed properly.
⑤ Make sure the Epoch-III-P8024/8030/8037NM is securely placed onto the wall bracket ⑥ Fasten the 8 bracket screws back properly ⑦ Inspect that everything is secure * Rack Mount option is also available. Please contact ADRF for additional information. Advanced RF Technologies, Inc. Proprietary Document Page 14 of 41...
Page 15
Epoch-III-P8024/8030/8037NM User Manual V1.6 Figure 7 – Repeater Mounting Instructions Advanced RF Technologies, Inc. Proprietary Document Page 15 of 41...
Epoch-III-P8024/8030/8037NM User Manual V1.6 2.3.3 Grounding A ground cable is included in the packaging and should be properly connected to the repeater as shown below. Figure 8 – Ground Cable Connection Advanced RF Technologies, Inc. Proprietary Document Page 16 of 41...
Epoch-III-P8024/8030/8037NM User Manual V1.6 2.3.4 Antenna Separation/Isolation Separation between the antennas is necessary to prevent oscillation. Oscillation occurs when the signal entering the system continually reenters, due to the lack of separation between the donor and server antennas. In other words, the signal is being fed back into the system.
Epoch-III-P8024/8030/8037NM User Manual V1.6 2.3.5 Line of Sight The donor antenna which points towards the base station typically has a narrow beam antenna pattern. As a result, a slight deviation away from the direction of the BTS can lead to less than optimum results. In addition, obstacles between the repeater and the BTS may impair the repeater from obtaining any BTS signal.
Epoch-III-P8024/8030/8037NM User Manual V1.6 3. Epoch-III-P8024/8030/8037NM AROMS Setup 3.1 Repeater/PC Connection Using AROMS i) Wait until the Power LED is lit in green. Connect the LAN cable between the laptop’s Ethernet port and the repeater’s Ethernet port. Note: Under Local Area Connection in Network Settings, make sure to select Obtain an IP address automatically under Internet Protocol (TCP/IP) properties.
Page 20
User Manual V1.6 Launch MS Internet Explorer (Version 6.0) Note: ADRF’s Web GUI has not been tested for compatibility with any other web browsers (e.g. Netscape, FireFox, Mozilla, etc.). iii) Please type the following IP address into the address bar of MS Internet Explorer: http://192.168.63.1/home.asp...
Epoch-III-P8024/8030/8037NM User Manual V1.6 3.2 Repeater Status If you click on Status tab, the following window will appear: In this window, the user can view the following: (To change any parameters, e.g., PCS Sub-Bands, Instantaneous Band Width, Gain Settings, AGC Level, etc., you must go to the Install or the Control window.)
Page 22
Repeater Info: Will display repeater’s serial number, and location information (latitude and longitude coordinates). Repeater Location: Will display the address where the repeater is installed Technical Support: Will display ADRF’s technical support contact information. Installer Contact Info: Will display the installer’s name, phone and e-mail address.
Epoch-III-P8024/8030/8037NM User Manual V1.6 3.3 Repeater Control If you click on Control tab, the following window will appear: In this window, the user can adjust the following parameters: General Setting - Automatic Gain Control (Default mode is Off) - Downlink HPA on/off (Default mode is On)
Page 24
Epoch-III-P8024/8030/8037NM User Manual V1.6 - Uplink AGC Level Epoch-III-P8024NM: 0 to 24 dBm @ 0.5 dB step, default value: 24 dBm Epoch-III-P8030NM: 0 to 30 dBm @ 0.5 dB step, default value: 30 dBm Epoch-III-P8037NM: 0 to 37 dBm @ 0.5 dB step, default value: 37 dBm - Uplink Tracking Offset (0 to 10 dB @ 0.5 dB step, default value: 3 dB)
Path 3, Path 1 and Path 3), or all three Paths (Three contiguous or non- contiguous sub-bands: Path1, Path 2 and Path 3). Therefore, the instantaneous bandwidth that the Epoch-III-P8024/8030/8037NM supports is 5, 10, 15, 20, 25 or 30 MHz.
Page 26
Installation box now changes from “Not Installed” to “Installed .” If the Epoch-III-P8024/8030/8037NM detects a problem during the installation process, it will show a prompt message, e.g., “Modem is not detected.” Please follow the instructions and address the problem to finish the installation process.
Epoch-III-P8024/8030/8037NM User Manual V1.6 3.5 Repeater System If you click on the System tab, the following window will appear: Note: If you are the Super-User, you will see account management section under the System Window. If you are a general user, you will not be able to see the account management portion.
Page 28
Epoch-III-P8024/8030/8037NM User Manual V1.6 The following window illustrates how the administrator can be changed by simply clicking on Administrator. Firmware Upgrade If you click on Firmware Upgrade, the following window will appear. You can browse through your PC and locate the firmware file. Once it’s selected, simply click on Update and it’ll upload the latest firmware automatically and close the...
Epoch-III-P8024/8030/8037NM User Manual V1.6 4. Maintenance Guide for Epoch-III-P8024/8030/8037NM 4.1 Periodic Inspection Checklist 4.1.1 Check for loose connections to the repeater and antennas. If connections are loose, make sure that all connections are tightly fastened properly. 4.1.2 Check that cables and connectors are in good condition.
User Manual V1.6 5. Warranty and Repair Policy 5.1 General Warranty The Epoch-III-P8024/8030/8037NM carries a Standard Warranty period of five (5) years unless indicated otherwise on the package or in the acknowledgment of the purchase order. 5.2 Limitations of Warranty Your exclusive remedy for any defective product is limited to the repair or replacement of the defective product.
Epoch-III-P8024/8030/8037NM User Manual V1.6 5.6 Return Material Authorization (RMA) No product may be returned directly to Advanced RF Technologies, Inc. without first getting an approval from Advanced RF Technologies, Inc. If it is determined that the product may be defective, you will be given an RMA number and instructions in how to return the product.
Epoch-III-P8024/8030/8037NM User Manual V1.6 A.4 Power Specifications Parameters Specifications Comments AC Power 100 ~ 130 AC AC Frequency 50 ~ 60 Hz AC Supply Protection Fuse DC Power Option -40 ~ -60 V / +20 ~ 30 V ≤ 95 W...
Modem box Port DHCP Sub Board Noise Filter UP/Down Converter Uplink UDC Uplink HPA Downlink UDC Downlink HPA Control Board Adapter for modem box Donor Port Duplexer Server Port Epoch-III-P8024/8030NM Internal Components Advanced RF Technologies, Inc. Proprietary Document Page 39 of 41...
Page 40
Epoch-III-P8024/8030/8037NM User Manual V1.6 Modem box Port Epoch-III-P8037NM: DHCP Sub Board Noise Filter Power Supply Adapter for modem box Downlink HPA Duplexer Uplink HPA Control Board Uplink UDC Downlink UDC UP/Down Converter Server Port Donor Port Epoch-III-P8037NM Internal Components Advanced RF Technologies, Inc. Proprietary Document...
Epoch-III-P8024/8030/8037NM User Manual V1.6 Power Supply It provides DC power to each module within the repeater. Controller It is responsible for monitoring the status of each module and controls the parameters. Also it interfaces with PC through Ethernet port. Down Converter Module The downlink RF signal that enters through the cavity filter is converted to IF frequency, which is later converted back to RF frequency through SAW filtering.