MAINTENANCE GUIDE FOR PSR-VU-9537-UBREPEATER

8.1

Periodic Inspection Checklist

1. Repeater
a.
Log into the ADRF unit and check for any alarms in the system
b. Address any outstanding alarms
c.
Check for loose connections to the repeaters/remotes and antennas. If connections are loose,
make sure that all connections are tightly fastened.
d. Check that cables and connectors are in good condition.
e.
Ensure that the repeater/remote brackets are in good condition and that the repeater/remote is
securely fastened.
Verify that the repeater has 3" of clearance on all sides to ensure proper ventilation.
f.
2. Battery Backup
a.
Open the ADRF-BBL-U/BBS-U enclosure and inspect the battery terminals for any corrosion
buildup
b. Turn the circuit breaker to the off position and unscrew the fuse holder to inspect the fuse
i. A spare fuse is included with the purchase of the ADRF-BBL-U and can be used to replace
c.
If the terminals need to be cleaned:
i. Set the ADRF-BBL-U/BBS-U breaker switch to the OFF position
ii. Disconnect the battery backup cable from the repeater
iii. Carefully disconnect battery terminals and clean the terminal with a battery terminal
iv. Wait for terminals to fully dry
v. Reconnect the battery terminals and set the breaker switch to the ON position
d. The lifespan of the batteries will vary based on the number of outages, however we approximate
that with an average of 4 outages a year, the batteries should last approximately 2-3 years
Advanced RF Technologies, Inc.

Figure 7-28 Help

the fuse if needed