7.3.1 General Settings

The General Settings section allows the user to enable/disable amplifiers and the ALC routine.
 ALC ON: Enables or disables Automatic Level Control (ALC)
 DL HPA On: Enables or disables the Downlink High Power Amplifier
 UL HPA On: Enables or disables the Uplink High Power Amplifier
 Remote Power Switch: Enables or disables the Remote Power Switch function. Note: Remote Power Switch
needs to be disabled for UL 2524.
To enable/disable any of the settings, click on the checkbox and click the Apply button.

7.3.2 System

Under the System section, the user is able to perform a soft reboot on the repeater and also can restore factory
default settings.
 Reboot: Performs a soft reboot of the repeater
 Factory Set: Restores all settings to factory defaults

7.3.3 Manual Gain Control

 DL/UL Gain: Gain levels of the repeater can be specified here
 DL/UL ALC Level: Prevents the output power from exceeding the specified value
 DL/UL Output ALC Offset: If any ALC attenuation has been applied, the system will release this attenuation
when the signal level drops by the specified level
Advanced RF Technologies, Inc.
Figure 7-10 Control Tab – General Setting
Figure 7-11 Control Tab – System
Figure 7-12 Control Tab – Manual Gain Control