4. ALARMS

4.1 Message Board Alarms and Notifications

Alarm
AC Input is outside of
AC Fail
operating range
DC Output is outside of
DC Fail
operating range
The module is above/below
Temperature
the normal operating
temperature
PSU is providing more than
Current
the max current
The system is in a shutdown
System Halt
state due to a hard fail alarm
The system has detected an
DSP Fault
issue with the internal DSP
OSC
Oscillation detected
DL signal is below the
DL Signal not detected
specified level
DL signal is below the
DL Signal Low
specified level
Incoming in-band DL or UL
Input Overload
signal is too strong
Incoming out-band DL or UL
Out of band Overload
signal is too strong
There is an issue with the
Synthesizer Lock Fail
internal PLL
Input + gain does not match
DL RF Power
the output level (above
delta of 6 dB)
The output level is above the
Overpower
max output levels
Power is being reflected
VSWR
back to the repeater
Heartbeat is sent out to the
Heartbeat
NOC
Reboot
Soft reboot performed
Factory default settings
Factory setting
restored
Door
Door alarm set/clear
4.2

External Alarms

The PSR-VU-9537-UBsupports dry contact alarms and can be connected to a fire alarm control panel. The user can program the
repeater to either create an open or closed circuit when an alarm is present in the system.
Advanced RF Technologies, Inc.
Table 4-1
Message Board Alarms and Notifications
Alarm Description
The power supply is not operating within specs. (4 seconds)
The power supply is not operating within specs. (4 seconds)
The module is above the normal operating temperature. (4
seconds)
Over Temperature [Soft: 80~87 C, Hard: Above 87 C]
The power supply is not operating within specs. (4 seconds)
Over Current [Hard: Above 20A]
The system is in a shutdown state due to a hard fail alarm. (10 cycles)
The system has detected an issue with the internal DSP chip. (Cannot
communicate with DSP)
Oscillation detected.
DL signal is below the specified level. (default: -90dBm, 4 seconds)
DL signal is below the specified level. (default: -85dBm, 4 seconds)
Input signal is above the threshold. (4 seconds)
(Soft: DL -5dBm/UL -5dBm, Hard: DL +5dBm/UL +5dBm)
Out of band signal is above the threshold. (4 seconds)
(Soft: DL -5dBm/UL -5dBm, Hard: DL +5dBm/UL +5dBm)
There is an issue with internal PLL. (4 seconds)
Input + gain does not match the output level.
(default delta of 6 dB)
The output level is above the max output levels.
AGC On case (Soft: AGC Level + 1~2dB, Hard: AGC Level + >2dB)
AGC Off case (Soft: max output level + 1~2dB, Hard: max output level
+ >2dB)
Power is being reflected back to the repeater. Threshold = output
power - 8dB. For example, if the repeater is outputting 24dBm and
detects 16dBm of return power, then the VSWR will be triggered.
(Alarm will only trigger when the output power is 15dBm or greater)
Heartbeat sent at set interval.
Reboot is performed from the Control tab.
Factory setting is set from the Control tab.
Door alarm set: Door open
Door alarm clear: Door close
Trigger Condition