3. ALARMS

3.1

Message Board Alarms and Notification

Parameters
AC Fail
DC Fail
Fan[1/2] Fail
Temperature
Current
System Halt
DSP Fault
OSC
DL Signal not detected
DL Signal Low
Input Overload
Out of band Overload
Synthesizer Lock Fail
DL RF Power
Overpower
VSWR
Heartbeat
Reboot
Factory setting
Sync Fail(SDR-ICS-43-BT only)
Advanced RF Technologies, Inc.
Table 3-1
Message Board Alarms and Notification
Power supply is not operating within specs
Power supply is not operating within specs
System has detected an issue with the fan1 and fan2
Module is above the normal operating temperature
Power supply is not operating within specs
System is in a shutdown state due to a hard fail alarm
System has detected an issue with the internal DSP chip
Oscillation detected
DL signal is below the specified level
DL signal is below the specified level
Incoming in-band DL or UL signal is too strong
Incoming out-band DL or UL signal is too strong
Issue with internal PLL
Input + gain does not match the output level (above delta of 6 dB)
Output level is above the max output levels
Power is being reflected back to the repeater
Heartbeat
Reboot
Factory setting
Sync Signal Not Detect, Sync Fail
Remark