4. INSTALLATION

4.1

Installation Procedures

4.1.1 Wall Mount Procedure

Verify that the SDRX-43-BTF and mounting hole are in good condition
Place the SDRX-43-BTF mounting template up against the wall and mark of mount holes
Mount the SDRX-43-BTF to wall use the six (6) mounting hole on the wall mount bracket
Connect the GND cable
Connect the Antenna cable
Connect the Power cable
Mount bracket
4.2

Grounding

Install the ground cable that is included in the package at the side of the repeater as show in the figure
below.
The grounding terminal is located at lower right-hand side of the BDA. The grounding cable should be
properly connected before powering on the equipment.
Ground terminals located on the side consisted of a 16mm²(6AWG) and should be permanently connected
to earth (Protective earthing conductor).
Advanced RF Technologies, Inc.
Figure 4-1
Wall Mount
Figure 4-2
Ground Cable Connection
20