Switch test (EASYswitch)
MP85A software (PME Assistant or INDUSTRYmonitor) and saved in the
results.
This analysis can be disabled separately for each switching operation ("Ignore
chatter").
A more extensive evaluation of chatter over time does not take place.
Information
The chatter of each individual switching operation is analyzed and plotted a
maximum of 16 times. If a switching process is subject to further chatter, the
measurement ends at this point.
Analysis, statistics and data logging are then only performed up until this point.
9.2
Haptic test
The haptic test determines how the switch in this window changes its state,
that is, the "feel" on actuation. You can enter the characteristic values required
for this in the haptic test dialog via the PME Assistant or INDUSTRYmonitor.
Any combination or all the characteristic values listed can be tested. The test is
NOK as soon as one of the enabled characteristic values is not OK. The indi
vidual characteristic values are clearly shown in the graph below.
88
A0293_06_E00_03 HBM: public
MP85A