S Standard ribbon cable, 10-pin, pitch 1.27 mm (4-3131.0037)
S Ethernet crossover cable, 2 m, (1‐KAB239‐2)
S Cable shield terminal (1-CON-A 1023)
3.4

General

The MP85A process controller from the PME product line is a twin-channel
amplifier, suitable for connecting transducers that use very different
technologies. As well as Ethernet and CAN, the MP85ADP(-S) also includes a
PROFIBUS interface, and in the MP85ADP‐PN(-S) the PROFIBUS interface
features a Profinet gateway.
"10V
SSI
MP85A(-S)/MP85ADP(‐S)/MP85ADP-PN(-S)
Fig. 3.1
Block diagram of the MP85A process controller
The PME Assistant provides a simple and free user interface for device
parameterization in Microsoft Windows. For this you will require an Ethernet
(crossover) cable (order no. 1‐KAB239‐2) for direction connection to a PC or a
USB → CAN interface converter (when using the CAN interface), which must
be ordered separately (order no.: 1‐PMESETUP‐USB).
16
Carrier frequency bridge
excitation voltage 4.8 kHz
Power supply for active sensors
5 V or 24 V
A
D
Intelligent signal conditioning and
powerful algorithms for monitoring
A
D
Keyboard and
display
A0293_06_E00_03 HBM: public
Power supply, electrically
EEPROM
joining processes
MMC/SD
memory card
isolated
μP
MP85A