8.3

Limit monitoring in real time

You can assign and monitor a total of eight limit values in real time for chan­
nels x and y. A switching signal of your choice can be assigned to each limit
value. For example, you can switch a press from "fast" to "slow". The circuit
logic can also be inverted.
8.4

Hiding external tolerances

To hide external tolerances, as caused by different positioning heights of
workpiece holders, for example, you have a choice of various options:
1. Relative x-coordinates
2. Relative y-coordinates
In the first case, you can also select whether analysis should be based on an
end position (Fig. 8.6) or on the y-channel (Fig. 8.7), e.g. if the pin being press-
fitted is touched (force build-up). Displacement is set to zero at this time, and a
second relative axis is plotted to which the coordinates of the evaluation ele­
ments now refer.
10
20
-60
Fig. 8.6
Reference values for relative x-coordinates, based on end position
MP85A
Measured curve
30
40
50
-50
-40
-30
-20
A0293_06_E00_03 HBM: public
End position
Absolute coordinates
60
70
-10
0
Relative coordinates, end value 0
Measurement procedure
75