Operation Instructions; Operation; Introduction; Operation From The Ground Control Box - Haulotte H12 SX Operator's Manual

Hide thumbs Also See for H12 SX:
Table of Contents

Advertisement

H12 SX - HS3388 RT - H12 SXL - HS3388 RT XL - H15 SX - HS4388 RT - H15 SXL - H18 SX - HS5388 RT - H18 SXL
D

- Operation instructions

Operation instructions

1 - Operation

1.1 -

INTRODUCTION

Only trained and authorized personnel shall be permitted to operate this aerial work platform.
Prior to operation :
• Read, understand and obey all instructions and safety precautions in this manual and attached to the
aerial work platform.
• Read, understand and obey all local regulations.
• Become familiar with the proper use of all controls and emergency systems.
1.2 -

OPERATION FROM THE GROUND CONTROL BOX

• Turning "ON" and "OFF" of the machine is performed with selector key switch (72).
• Activation of a desired control box is achieved by turning the control box energizing selector
switch ( 72 ) to the desired position.
• The ground control box is energized and is active ONLY when :
• The E-stop buttons on both ground and platform control boxes are not pressed in.
• The machine is switched on.
• Ground control box is selected.
• An EMERGENCY STOP button located on each control box stops all movements and shuts off the
engine when pressed in.
• When the engine is running, the switch ( 72 ) operates as an activation control only.
• An Enable Switch ( 72 ) provided must be activated and maintained to authorize one or more function
movements. If Enable Switch ( 72 ) is kept engaged without selecting a function movement for more
than 8 s; Enable Switch is automatically de-activated.
• Only movements of lifting and lowering the platform are possible from the ground control box.
• All switches and joystick operating a movement, return automatically to neutral when released.
• Enable Switch / Emergency pump
• Engine running, the switch acts as an Enable Switch only.
• Engine stopped, the switch acts as the Enable switch and operate the emergency pump control.
• Overriding system : The ground control box is designed for maintenance and emergency rescue
operations only. Refer to
4001011590
Section D 4.2 - To rescue operator in platform.