Table of Contents

Advertisement

MAINTENANCE

Make sure that all parts are properly tightened each time the weight system is used. Replace any worn
parts immediately. Use only manufacturer-supplied parts. The weight system can be cleaned with a damp
cloth and a mild, non-abrasive detergent; do not use solvents.
TIGHTENING THE CABLES
Woven cable, the type of cable used on the weight system, can stretch slightly when it is first used. If there is
slack in the cables before resistance is felt, the cables should be tightened. To tighten the cables, first insert the
weight pin into the middle of the weight stack. Slack can be removed from the cables several ways:
See the inset drawing. Tighten the M6 Locknut (84)
that connects the end of the Low Cable (53) to the
48
U-bracket (45).
50
43
56
To further tighten the cables, remove the M10
43
Locknut (56) and the M10 x 50mm Bolt (66) from
the Cable Trap (50), the Pulley (48), the two Half
Guards (43), and the U-bracket (45). Reattach the
66
Pulley, Cable Trap, and Half Guards to the other hole
in the U-bracket. Make sure that the Cable Trap is
45
53
in the proper position and that the Low Cable (53)
84
45
and Pulley move smoothly.
53
To further tighten the cables, loosen the M12 Nut (82)
on the High Cable (55). Next, tighten the High Cable
55
into the Weight Selector (24) until the slack is removed
82
from the High Cable. Then, retighten the M12 Nut
against the Large Washer (78).
78
24
Do not overtighten the cables. If the cables are overtightened, the top weight will be lifted off the weight
stack. If a cable tends to slip off the pulleys often, it may have become twisted. Remove the cable and
reinstall it. If the cables need to be replaced, see ORDERING REPLACEMENT PARTS on the back cover of this
manual.
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wesy19318.2

Table of Contents