MAINTENANCE

Make sure that all parts are properly tightened each time you use the weight bench. Replace any worn parts
immediately. Clean the weight bench with a damp cloth and mild, non-abrasive detergent; do not use solvents.

TIGHTENING THE CABLES

Woven cable, the type of cable used on the weight bench, can stretch slightly when it is fi rst used. If there is slack
in the cables before resistance is felt, the cables should be tightened. Make sure that the cables are not too tight,
or the weight carriage will be lifted. Slack can be removed in the following ways:
Remove the M10 x 50mm Bolt (104) and the M10
Locknut (79) attaching the 90mm Pulley (58) and
72
the Plastic Cable Trap (63) to the Long Double
U-bracket (47). Reattach the 90mm Pulley and the
Plastic Cable Trap to a higher set of holes in the
47
79
U-bracket with the Bolt and the Locknut.
104
58
63
54
Additional slack can be removed from the cables
by tightening a cable into the M6 Locknut (100)
100
inside a Clip (53). To do this, slide the Cable Stop
(52) away from the Clip and use a pair of pliers or a
Cable
screwdriver to tighten the Locknut. Then, replace the
Cable Stop.
52
53
Do not overtighten the cables. If a cable tends to slip off the pulleys often, the cable may have become
twisted. Remove the cable and reinstall it. If a cable needs to be replaced, see the back cover of this manual.