DC Input

8
The device is suitable to be supplied from a DC input voltage. Use a battery or a
similar DC source. A supply from the intermediate DC-bus of a frequency
converter is not recommended and can cause a malfunction or damage the
unit. Connect +pole to L, –pole to N and the PE terminal to an earth wire or to
the machine ground.
DC input
DC input range
DC input current
Allowed Voltage (+) or (-)
input to Earth
Turn-on voltage
Shut-down voltage
Figure 5 - Wiring for DC Input
Battery
+
-
Rockwell Automation Publication 1606-RM110A-EN-P - July 2020
Nom DC 110...150V
±20% for 1606-XLE240ER...
Nom DC 110...300V
±20% for 1606-XLE240EC...
88...180V DC
Continuous operation for 1606-XLE240ER...
Min
88...360V DC
Continuous operation for 1606-XLE240EC...
Typ 2.35 A
At 110V DC and 10 A load current
Typ 0.84 A
At 300V DC and 10 A load current
Max 360V DC
Continuous according to IEC 60664-1
Typ 80V DC
Steady state value
70V DC
Steady state value
Typ
55V DC
Dynamic value (max 250 ms)
Power Supply
AC
L
+
N
Load
PE
-
DC