Bulletin 1606 Switched Mode Power Supplies
Catalog Numbers: 1606-BATASSY2, 1606-XLSBAT2, 1606XLSBATBR2
Terminology and Abbreviations
• DC-UPS—Uninterruptible power supply with DC Input.
• Normal mode—Describes a condition in which the battery is charged, the input voltage is in range and the output is loaded within the
allowed limits.
• Buffer mode—Describes a condition where the input voltage is below the transfer threshold level, the unit is running on battery (buffering)
and the output is loaded within the allowed limits.
• Charging mode—Describes a condition where the battery is in the process of charging, the input voltage is in range and the output is loaded
within the allowed limits.
• Inhibit mode—Describes a condition where buffering is intentionally disabled by using the inhibit input of the DC UPS (e.g. to perform
service actions or to save battery capacity).
• Buffer time—This term is equivalent to "hold-up time."
• T.b.d.—To be defined, value or description will follow later.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1606-BATASSY2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Allen-Bradley 1606-BATASSY2

  • Page 1 Reference Manual Bulletin 1606 Switched Mode Power Supplies Catalog Numbers: 1606-BATASSY2, 1606-XLSBAT2, 1606XLSBATBR2 Terminology and Abbreviations • DC-UPS—Uninterruptible power supply with DC Input. • Normal mode—Describes a condition in which the battery is charged, the input voltage is in range and the output is loaded within the allowed limits.
  • Page 2: Battery Modules

    Bulletin 1606 Switched Mode Power Supplies Battery Modules A modular concept allows the user to meet individual application demands and is available with two different options: You can order the module with an assembled battery or you can choose only the bracket allowing the mounting of individual batteries.
  • Page 3: Intended Use

    Bulletin 1606 Switched Mode Power Supplies Intended Use • This device is designed for installation in an enclosure and is intended for the general professional use such as in industrial control, office, communication, and instrumentation equipment. • Do not use this power supply in aircraft, trains, nuclear equipment or similar systems where malfunction may cause severe personal injury or threaten human life.
  • Page 4: Physical Dimensions

    Bulletin 1606 Switched Mode Power Supplies Physical Dimensions Fig. 1 Front view Fig. 2 Side view Panel/Wall Mounting The battery module can be mounted in upright or table-top position. Fig. 2 Hole pattern All parameters are specified at 25°C ambient unless noted otherwise. Rockwell Automation Publication 1606-RM039A-EN-P —...
  • Page 6: Rockwell Automation Support

    Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products. At http://www.rockwellautomation.com/support, you can find technical manuals, technical and application notes, sample code and links to software service packs, and a MySupport feature that you can customize to make the best use of these tools.

This manual is also suitable for:

1606-xlsbat21606xlsbatbr2

Table of Contents