between the coals causing an imperfect flame.
Check that soot or debris is not impairing the electrode spark or pilot burner.
!
Check that soot or debris is not blocking any of the holes in the main burner.
!
After servicing, make sure that the ceramic rear wall and coals are
!
replaced correctly as described in the installation instructions.
Always test for gas soundness and spillage after servicing the appliance.
!

17.1 Checking the aeration setting of the burner.

1. The aeration collar is factory set and will require adjustment.
It is important to ensure that the aeration setting is
correct (See
figure 31).
2. To adjust the aeration setting, loosen the two aeration shutter
screws, slide the aeration shutter to the position shown in figure
31 and tighten the fixing screws.

17.2 To Remove the Fire Front Surround

1. Remove the bottom front cover casting.
2. Lift the fire front casting clear. (Where applicable by lifting
the fire front casting up and forward to release the locating
screw heads at the back of the casting from the keyholes in the
surround sides.)
3. Remove the two screws
securing the bottom of the
front surround to the sides of
the convection box. Raise the
front surround to allow the
retaining lugs at the top to
clear the slots in the
convection box hood and then
lift clear. See figure 32.
4. Replace in the reverse order.
INSTALLER GUIDE
Figure 32. Front Surround removal
Page 31
Figure 31. Aeration
collar settings