Programming With Dna - CAME BPT DVC/01 Programming Manual

Table of Contents

Advertisement

PROG
PROG
>3''
>3''
K
Programming entry panel video cameras. While programming the call keys the "visual range" of the video camera can be adjusted
in the way already described.
Entry panel brightness level adjustment. While programming the call keys the entry panel brightness level can be adjusted in the
way already described.
Should call keys be present ONLY ON ADDITIONAL BUTTON PANELS, proceed as shown in the NOTE on page 6.
WARNING. If an entry panel is added, replaced or moved, the modifi cations are acquired by going into "Programming Type
of Keys" (from fi gure 6-K).

Programming with DNA

1
2
For this type of confi guration of Entry
3
4
panels refer to the procedures already
5
6
7
described.
8
9
10
PROG
PROG
>3''
>3''
1
1 P.E
2
PROG
PROG
>3''
>3''
3
5
If all the entry panels are reprogrammed, the confi guration will be as shown in fi gure
J. To exit reprogramming, briefl y press the PROG key on the power supply K: the
PROG LEDs and the LEDs on the entry panels will go out. If no action is performed, the
procedure will end automatically after 30 minutes.
Entering Programming Mode. Press the PROG key on the power supply for more than
3 seconds 1. The LEDS on the entry panels light up as shown in fi gure 2. If the PROG
LED immediately goes out, this indicates a malfunction in the connections between the
power supply and the entry panel. Check the connections and return to programming.
Repeat the operation 3 a second time. Check that the confi guration on the Entry panels
is as shown in fi gure 4. Wait 5 seconds for the auto test to be completed and continue
as shown below.
2 P.E
3 P.E
1 P.E
4
XX
XX
6
For this type of confi guration of Entry panels refer
to the procedures described below.
Programming the call codes. Press the door release
buttons 5. Enter the call code for the group (from 1
AUX2
to 99), followed by the
receiver. Continue, repeating the same operations for all the other
receivers. The operation can only be carried out from the entry
panel with the
LED off (PE1 4): to change the entry panel
from which to carry out the programming of calls, press key 1
followed by the
key.
2 P.E
beep
beep
+
key 6 to link the call code to the
3 P.E
and

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bpt dvc/01meBpt dc/01Bpt dc/01me

Table of Contents