Pairing Secure Lock Relay with Call Panel

6 Pairing Secure Lock Relay with Call Panel
6.1

Confirm Door No. of Call Panel

i.
Connect a laptop or PC to the same network as the Call Panel.
ii.
Use a web browser and enter the IP address of the Call Panel in to the address bar.
iii.
Login to the call panel using the username admin and the device admin password.
iv.
Navigate to Local Settings > Basic.
v.
Check the Door No. - each Call Panel on a block should have a unique number.
6.2

Secure Lock Relay RS485 Address

The Secure Lock Relay has connections for up to 4 doors and must have the RS485
address corresponding to the last 2 digits within the Door No. of the associated Call Panels.
The RS485 address must correspond to the address of the 1
subsequent Call Panels Door No. are incremented. E.g.
o 4 Doors numbered 8001-8004 = RS485 address 1.
o 4 Doors numbered 8105-8109 = RS485 address 5.
SW1 Switches 1-4 set the binary address (0-15).
ON = 1
OFF = 0
Switch
Binary Value
Address 0
Address 1
Address 3
Address 7
Address 15
10
FIGURE 6-1
1
2
3
1
2
4
0
0
0
1
0
0
1
1
0
1
1
1
1
1
1
FIGURE 6-2 - BINARY ADDRESS TABLE