Reprogramming Procedure - CAME BPT DVC/01 Programming Manual

Table of Contents

Advertisement

Exiting Programming. Briefl y press the PROG key on the power supply: the PROG LEDs and the LEDs on the entry panels will go out.
NOTE. If no action is performed, the procedure will end automatically after 30 minutes.
Programming entry panel video cameras. While programming the call keys the "visual range" of the video camera can be adjusted
in the way already described.
Entry panel brightness level adjustment. While programming the call keys the entry panel brightness level can be adjusted in the
way already described.

Reprogramming Procedure

PROG
PROG
>3''
>3''
1
2
3
PROG
PROG
>3''
>3''
6
1 P.E
7
1 P.E
I
Entering Programming Mode. Press the PROG key on the power supply 1 until the
PROG LED lights up. The LEDS on the entry panels light up as shown in fi gure 2. Wait
5 seconds for the auto test to be completed and continue as shown below.
Programming the call keys. Press the door release
entry panel, press the call key to be linked to the receiver 4: a beep will confi rm that
the setting has been stored. Continue, repeating the same operations for all the other
4
Exiting Programming. Briefl y press the PROG key on the power supply 5: the PROG
LEDs and the LEDs on the entry panels will go out. If no action is performed, the proce-
dure will end automatically after 30 minutes.
Programming Type of Keys. In "Programming Call Keys" 6 press and hold down the
PROG key of the power supply until you go into the "Programming Type of Keys" pro-
cedure 7. Press one of the fi rst 4 "keys" on the entry panels to be reprogrammed, the
LED will stop fl ashing, as will the backlighting LEDs of the fi rst 4 positions of the call
keys 8. Repeat this operation on all the entry panels to be reprogrammed 8 and I.
2 P.E
3 P.E
2 P.E
3 P.E
receivers. The operation can be carried out only from the entry
panel with the
from which to carry out the call programming, press one of the
fi rst 4 positions of the call keys for at least 3 seconds (or press
key 1 followed by the
beep
beep
1 P.E
H
1 P.E
J
and AUX2 buttons 3. On the
LED off (PE1 2): to change the entry panel
key for entry panels with DNA).
PROG
PROG
<1''
<1''
5
2 P.E
2 P.E
3 P.E
3 P.E

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bpt dvc/01meBpt dc/01Bpt dc/01me

Table of Contents