S0700
T
Kit (Terminal Block)
b This kit has a small terminal box inside a junction
box. The electrical entry port {G 3/4} permits connec-
tion of conduit fittings.

Terminal Block Connection

Step 1. How to remove terminal block cover
Loosen the 4 mounting screws (M4) and open the terminal
block cover.
Mounting screw (M4)
Step 3. How to replace terminal block cover
Securely tighten the screws with the torque shown in the table
below, after confirming that the gasket is installed correctly.
Proper tightening torque (N·m)
0.7 to 1.2
Electrical Wiring Specifications
Double wiring (connected to SOL. A
and SOL. B) is adopted for the internal
wiring of each station, regardless of
valve and option types.
Mixed single and double wiring is avail-
able as an option.
Note) Mounting valve have no
polarity. It can also be used
as a negative common.
636
Terminal block cover
Gasket
• Applicable crimp terminal: 1.25-3S,1.25Y-3,1.25Y-3N,1.25Y-3.5
Standard wiring
Terminal
no.
SOL.A
1A
1 station
SOL.B
1B
SOL.A
2A
2 stations
SOL.B
2B
SOL.A
3A
3 stations
SOL.B
3B
SOL.A
4A
4 stations
SOL.B
4B
SOL.A
5A
5 stations
SOL.B
5B
SOL.A
6A
6 stations
SOL.B
6B
SOL.A
7A
7 stations
SOL.B
7B
SOL.A
8A
8 stations
SOL.B
8B
SOL.A
9A
9 stations
SOL.B
9B
SOL.A
10A
10 stations
SOL.B
10B
COM
Positive
common
specification
Step 2. The diagram below shows the terminal block wiring
schematic. All stations are provided with double
solenoid wiring.
Connect each wire to the power supply side, according
to the markings provided inside the terminal block.
Electrical entry
2-G3/4
Special Wiring Specifications (Option) [-K]
Polarity
Mixed single and double wiring are available as an option.
The maximum number of manifold stations is determined by
(–)
(+)
the number of solenoids. Count one point for a single sole-
(–)
(+)
noid type and two points for a double solenoid type. The total
(–)
(+)
number of solenoids (points) must not exceed 20.
(–)
(+)
1. How to order valves
(–)
(+)
Indicate an option symbol, -K, for the manifold no. and be
(–)
(+)
sure to specify the mounting position and number of stations
of the single and double wiring by means of the manifold
(–)
(+)
specification sheet.
(–)
(+)
2. Wiring specifications
(–)
(+)
Connector terminal numbers are connected from solenoid
(–)
(+)
station 1 on the A side in the order indicated by the arrows
(–)
(+)
without shipping any terminal numbers.
(–)
(+)
(–)
(+)
(–)
(+)
(–)
(+)
(–)
(+)
(–)
(+)
(–)
(+)
(–)
(+)
(–)
(+)
(+)
(–)
Note)
Negative
common
specification
M3 screw