SMC Networks S0700 Series Manual page 20

7 mm width compact pilot type 5 port solenoid valve
Hide thumbs Also See for S0700 Series:
Table of Contents

Advertisement

S0700
P
Kit (Flat Ribbon Cable)
b Flat ribbon cable connector reduces installation labor for elec-
trical connection.
b Using the connector for flat ribbon cable (26P, 20P) conform-
ing to MIL standard permits the use of connectors put on the
market and gives a wide interchangeability.
b Top or side receptacle position can be selected in accordance
with the available mounting space.
Electrical Wiring Specifications
Flat ribbon cable connector
Double wiring (connected to SOL. A and SOL.
26
25
B) is adopted for the internal wiring of each
24
23
station, regardless of valve and option types.
22
21
Mixed single and double wiring is available as
20
19
an option. For details, refer to "Special Wiring
18
17
Specifications" (Option) below.
16
15
14
13
12
11
10
9
8
7
6
5
Connector terminal no.
4
3
Triangle mark
2
1
indicator position
<26P>
Terminal
Polarity
no.
SOL.A
(–)
(+)
1
1 station
SOL.B
2
(–)
(+)
SOL.A
3
(–)
(+)
2 stations
SOL.B
(–)
(+)
4
SOL.A
(–)
(+)
5
3 stations
SOL.B
(–)
(+)
6
SOL.A
(–)
(+)
7
4 stations
SOL.B
8
(–)
(+)
SOL.A
9
(–)
(+)
5 stations
SOL.B
(–)
(+)
10
SOL.A
(–)
(+)
11
6 stations
SOL.B
(–)
(+)
12
SOL.A
(–)
(+)
13
7 stations
SOL.B
14
(–)
(+)
SOL.A
15
(–)
(+)
8 stations
SOL.B
(–)
(+)
16
SOL.A
(–)
(+)
17
9 stations
SOL.B
(–)
(+)
18
SOL.A
(–)
(+)
19
10 stations
SOL.B
20
(–)
(+)
SOL.A
21
(–)
(+)
11 stations
SOL.B
(–)
(+)
22
SOL.A
(–)
(+)
23
12 stations
SOL.B
(–)
(+)
24
COM.
25
(+)
(–)
COM.
(+)
(–)
26
Positive
Negative
common
common
specification
specification
Note) Mounting valve have no polarity. It can also be used as a
negative common.
628
<20P>
Terminal
Polarity
no.
SOL.A
(–)
(+)
1
1 station
SOL.B
2
(–)
(+)
SOL.A
3
(–)
(+)
2 stations
SOL.B
(–)
(+)
4
SOL.A
(–)
(+)
5
3 stations
SOL.B
(–)
(+)
6
SOL.A
(–)
(+)
7
4 stations
SOL.B
8
(–)
(+)
SOL.A
9
(–)
(+)
5 stations
SOL.B
(–)
(+)
10
SOL.A
(–)
(+)
11
6 stations
SOL.B
(–)
(+)
12
SOL.A
(–)
(+)
13
7 stations
SOL.B
14
(–)
(+)
SOL.A
15
(–)
(+)
8 stations
SOL.B
(–)
(+)
16
SOL.A
(–)
(+)
17
9 stations
SOL.B
(–)
(+)
18
COM.
19
(+)
(–)
COM.
(+)
(–)
20
Positive
Negative
common
common
specification
specification
Note)
Cable Assembly
1
20
AXT100-FC
-
2
26
3
Type 26P flat ribbon cable connector assemblies can be ordered
with manifolds. Refer to "How to Order Manifold".
Terminal no.
6
(15.6)
Flat Ribbon Cable Connector Assembly (Option)
Cable
length (L)
26P
1.5 m
AXT100-FC26-1
3 m
AXT100-FC26-2
5 m
AXT100-FC26-3
∗ For other commercial connectors, use a 20 or 26 pins type with
strain relief conforming to MIL-C-83503.
∗ Cannot be used for transfer wiring.
Connector manufacturers' example
• Hirose Electric Co., Ltd.
• Japan Aviation Electronics Industry, Ltd.
• Sumitomo 3M Limited
• J.S.T. Mfg. Co., Ltd.
• Fujitsu Limited
• Oki Electric Cable Co., Ltd.
Special Wiring Specifications (Option) [-K]
COM.
COM.
26
25
COM.
24
23
22
21
20
19
20
19
18
17
18
17
16
15
16
15
14
13
14
13
12
11
12
11
10
9
10
9
8
7
8
7
6
5
6
5
4
3
4
3
2
1
2
1
(For 26P)
(For 20P)
28AWG
Red
L
Assembly part no.
20P
AXT100-FC20-1
AXT100-FC20-2
AXT100-FC20-3
Mixed single and double wiring
are available as an option. The
maximum number of manifold
stations is determined by the
number of solenoids. Count one
COM.
point for a single solenoid type
and two points for a double sole-
noid type. The total number of
solenoids (points) must not ex-
ceed 24 for 26P, 18 for 20P.
1. How to order valves
Indicate an option symbol, -K,
for the manifold no. and be sure
to specify the mounting position
and number of stations of the
single and double wiring by
means of the manifold specifica-
tion sheet.
2. Wiring specifications
Connector terminal numbers are
connected from solenoid station
1 on the A side in the order indi-
cated by the arrows without
shipping any terminal numbers.