SMC Networks S0700 Series Manual page 33

7 mm width compact pilot type 5 port solenoid valve
Hide thumbs Also See for S0700 Series:
Table of Contents

Advertisement

Kit name / Cable length
Kit
Symbol
Specification
name
LD0
Lead wire, with 0.6 m cable
L kit
LD1
Lead wire, with 1.5 m cable
LD2
Lead wire, with 3.0 m cable
Note) The maximum number of stations is determined by the total number of solenoids.
For mixed single and double wirings, enter "-K" to the order code options.
Type of actuation
Single type
Number of solenoids
How to Order Valves
Type of actuation
Symbol
Specification
1
2 position single
2
2 position double
4 position dual 3 port type (N.C. + N.C.)
A
[Exhaust center]
4 position dual 3 port type (N.O. + N.O.)
B
[Pressure center]
C
4 position dual 3 port type (N.C. + N.O.)
Note) For JIS symbol, refer to page 616.
Base mounted plug-in
How to Order Manifold
SS0750
Stations
Symbol
Stations
02
2 stations
Note)
24
24 stations
Note) The maximum number of stations
will be different depending on the
wiring specification.
Cylinder port size
Symbol
Port size
ø
C2
With one-touch fitting for
ø
C3
With one-touch fitting for
ø
C4
With one-touch fitting for
Note)
CM
Mixed size/with port plug
ø
N1
With one-touch fitting for
ø
N3
With one-touch fitting for
Note)
NM
Mixed size/with port plug
Note) Specify "Mixed size/with port plug" in the manifold
specification sheet.
Max. number of
stations for special
Standard station
wiring specification
1 to 12 stations
24 stations
Double, Dual 3 port type
1
2
S07 1 0
Function
Symbol
Nil
R
Note) Not compatible with dual 3 port valves.
08 C4
LD0
2
3.2
Metric
4
1/8"
5/32"
Inch
Max. number of
solenoids
24
5
Voltage
Symbol
Specification
5
24 VDC
6
12 VDC
Specification
Standard
Note)
External pilot
S0700
Plug-in
B
Option
Symbol
Option
Nil
None
With back pressure check valve
Note 2)
B
(all stations)
D
With DIN rail (Rail length: Standard)
D0
Without DIN rail (with bracket)
With DIN rail Designated length
D „
Note 3)
(„: station)
Special wiring specification (Except
Note 4)
K
double wiring)
N
With name plate
Note 5)
R
External pilot
S
Built-in silencer
Note 1) When two or more options are specified,
indicate them alphabetically. Example) -BKN
Note 2) When installing a back pressure check valve
on the required station, enter the part number
and specify the station position in the manifold
specification sheet.
Note 3) The available number of stations is larger than
the number of manifold stations.
Note 4) Indicate the wiring specification for mixed
single and double wirings.
Note 5) For details, refer to page 648.
∗ For manifold optional parts, refer to pages 648 to
652.
∗ For manifold exploded view, refer to page 654.
How to Order Manifold Assembly
Specify the part numbers for valves and
options together beneath the manifold base
part number.
<Example>
Lead wire kit
1 set – Manifold base part no.
SS0750-08C4LD0 ···
∗ S0710-5 ················
3 sets – Valve part no. (Stations 1 to 3)
∗ S0720-5 ················
2 sets – Valve part no. (Stations 4 to 5)
∗ S07A0-5 ················
2 sets – Valve part no. (Stations 6 to 7)
∗ SS0700-10A-1 ······
1 set – Blanking plate part no. (Station 8)
Write sequentially from the
1st station on the D side.
Prefix the asterisk to
When part nos. written
collectively are complicated,
the part nos. of the
specified by using the
solenoid valve, etc.
manifold specification sheet.
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
641