Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) , and other safety regulations.
Page 4
Safety Instructions Caution The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch.
SV Series 5 Port Solenoid Valve / Precautions 1 Be sure to read before handling. Design / Selection 9. Regarding a vacuum switch valve and a Warning vacuum release valve 1. Confirm the specifications. If a non-vacuum valve is installed in the middle of piping...
SV Series 5 Port Solenoid Valve / Precautions 2 Be sure to read before handling. Design / Selection Caution 2. Leakage voltage Take note that the leakage voltage will increase when a resistor is used in parallel with switching element or a C-R...
SV Series 5 Port Solenoid Valve / Precautions 3 Be sure to read before handling. Tighten with the proper torque shown below. Mounting Tightening torque for fitting Warning Connection thread Proper tightening torque (N・m) 4. If air leakage increases or equipment does not...
SV Series 5 Port Solenoid Valve / Precautions 4 Be sure to read before handling. Air Supply 2. Products with IP65 and IP67 enclosures (based on IEC60529) are protected against dust and Warning water. However, these products cannot be used in water.
SV Series 5 Port Solenoid Valve / Precautions 5 Be sure to read before handling. Maintenance UL approved Warning Caution 1. Perform maintenance inspection according to When conformity to UL is required, the SI unit should be the procedures indicated in the operation used with a UL 1310 Class 2 power supply.
Page 10
In the case of using a 5 port valve (as a 3 port valve) The SV series can be used as normally closed (N.C.) or normally open (N.O.) 3 port valves by closing one of the cylinder ports (A or B) with a plug.
Page 11
SV Series Specific Product Precautions 2 Be sure to read this before handling. If cutting is done with tools other than tube cutters, there is Manifold Mounting the danger that the tube may be cut diagonally or become flattened, etc., making a secure installation impossible, and...
TROUBLESHOOTING Should any trouble be found during operation, trace the source of the trouble in the following order and take corrective action. Trouble phenomenon Cause expected Measures ① Faulty operation Pilot valve is not operated Fall of power supply voltage. ②...
Remedy Remedy ① Regulate voltage, so that the voltage at the time of the operation becomes specifications range. ② Re-wire correctly. ③ Replace part. ④ Replace part or re-wire positively. ⑤ Replace valve. ⑥ Regulate pressure so that pilot pressure will fall within operating pressure range furing operation. ・If wrong oil is used, completely air blow to remove oil, and replace valve.