SMC Networks S0700 Series Manual page 54

7 mm width compact pilot type 5 port solenoid valve
Hide thumbs Also See for S0700 Series:
Table of Contents

Advertisement

S0700
S
Kit (Serial Transmission System)
SS0755
Stations
Symbol
Stations
02
2 stations
16
16 stations
Note) The maximum number of stations is determined by the total number of solenoids.
For mixed single and double wirings, enter "-K" to the order code options.
Max. number of
Standard
Max. number of
stations for special
station
wiring specification
1 to 8 stations
16 stations
Type of actuation
Single type
Number of solenoids
Refer to pages 1696 to 1724 for the details of EX510 gateway system
serial transmission system.
How to Order Valves
S07 1 5
Type of actuation
Symbol
Specification
1
2 position single
2
2 position double
4 position dual 3 port type
A
(N.C. + N.C.)
[Exhaust center]
4 position dual 3 port type
B
(N.O. + N.O.)
[Pressure center]
4 position dual 3 port type
C
(N.C. + N.O.)
Note) For JIS symbol, refer to page 616.
Base mounted plug lead
Symbol
Specification
Nil
Standard
R
External pilot
Note) Not compatible with dual 3 port valves.
662
How to Order Manifold
SA
S kit
EX510 serial wiring
SI unit COM.
Nil
+COM.
N
–COM.
solenoids
16
Double, Dual 3 port type
1
2
5 MO
Voltage: 24 VDC
Function
Note)
EX510 Gateway System Serial Transmission System
08 C4
P, R Port thread type
Symbol
Nil
F
N
T
Cylinder port size
Symbol
M5
M5 thread
C2
With one-touch fitting for ø2
C3
With one-touch fitting for ø3.2
C4
With one-touch fitting for ø4
CM
Mixed size/with port plug
N1
With one-touch fitting for ø1/8"
N3
With one-touch fitting for ø5/32"
NM
Mixed size/with port plug
Note) Specify "Mixed size/with port plug" in the manifold
specification sheet.
Electrical entry
M plug connector, without lead wire
(Light/surge voltage suppressor)
Option
Option
Symbol
Nil
None
Special wiring specification
K
Note 2)
(Except double wiring)
Note 3)
R
External pilot
Note 1) When two or more options are specified,
indicate them alphabetically. Example) -KR
Note 2) Indicate the wiring specification for mixed
single and double wirings.
Note 3) For details, refer to page 664.
∗ For manifold optional parts, refer to pages 664
to 666.
Manifold pitch
8.5
Rc (PT)
G (PF)
NPT
NPTF
Port size
Metric
Note)
Inch
Note)
How to Order Manifold Assembly
Specify the part numbers for valves and op-
tions together beneath the manifold base
part number.
<Example>
Lead wire kit
SS0755-SA08C4 ·····
1 set – Manifold base part no.
∗ S0715-5G ··············
3 sets – Valve part no. (Stations 1 to 3)
∗ S0725-5G ··············
3 sets – Valve part no. (Stations 4 to 6)
∗ S07A5-5G ··············
2 sets – Valve part no. (Stations 7 to 8)
Write sequentially from the
1st station on the D side.
When part nos. written
Prefix the asterisk to
collectively are complicated,
the part nos. of the
specified by using the
solenoid valve, etc.
manifold specification sheet.
The connector assembly lead
wire length used for EX510
manifold varies depending on
the number of stations.
Therefore, solenoid
valves (including a
blanking plate) and
connector
assembly are
assembled when
shipped as a
standard
specification.
Please specify the
mounting solenoid
valve when
ordering.