SMC Networks SJ4000 Series Operation Manual

Solenoid valve
Hide thumbs Also See for SJ4000 Series:

Advertisement

Quick Links

Doc. No. SJ2000-OMM0001-C
Solenoid Valve
PRODUCT NAME
SJ1000/2000/3000/4000 Series
MODEL/ Series

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SJ4000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for SMC Networks SJ4000 Series

  • Page 1 Doc. No. SJ2000-OMM0001-C Solenoid Valve PRODUCT NAME SJ1000/2000/3000/4000 Series MODEL/ Series...
  • Page 2: Table Of Contents

    Contents Contents ---------------------------------------------------------------------------------------------- 1 Safety Instructions ---------------------------------------------------------------------------------- 2,3 Design / Selection ----------------------------------------------------------------------------------- 4,5 Mounting -------------------------------------------------------------------------------------------- 5 Piping ------------------------------------------------------------------------------------------------ 6 Wiring ------------------------------------------------------------------------------------------------ 6 Lubrication ------------------------------------------------------------------------------------------ 6 Air Supply ---------------------------------------------------------------------------------------------- 6,7 Operating Environment ----------------------------------------------------------------------------- 7 Maintenance ------------------------------------------------------------------------------------------- 7 UL approved ---------------------------------------------------------------------------------------- 7 Valve Construction ---------------------------------------------------------------------------------- 8 to 17 Specific Product Precautions --------------------------------------------------------------------- 18 to 24...
  • Page 3: Safety Instructions

    Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) , and other safety regulations.
  • Page 4 Safety Instructions Caution The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch.
  • Page 5: Design / Selection

    SJ1000/2000/3000/4000 Series Precautions for 4 Port Solenoid Valve 1 Be sure to read before handling. Refer to main text for detailed precautions on every series. Design / Selection 11. Ventilation Provide ventilation when using a valve in a confined area, such as in a closed control panel.
  • Page 6: Mounting

    SJ1000/2000/3000/4000 Series Precautions for 4 Port Solenoid Valve 2 Be sure to read before handling. Refer to main text for detailed precautions on every series. 5. Operation in low temperature conditions Design / Selection It is possible to operate a valve in extreme temperatures, as low as –10°C.
  • Page 7: Piping

    SJ1000/2000/3000/4000 Series Precautions for 4 Port Solenoid Valve 3 Be sure to read before handling. Refer to main text for detailed precautions on every series. With diode to protect polarity. Piping If polarity connection is wrong, the valve will not operate.
  • Page 8: Operating Environment

    SJ1000/2000/3000/4000 Series Precautions for 4 Port Solenoid Valve 4 Be sure to read before handling. Refer to main text for detailed precautions on every series. Air Supply Maintenance 1. When extremely dry air is used as the fluid, 1. Perform maintenance and inspection according degradation of the lubrication properties inside to the procedures indicated in the operation the equipment may occur, resulting in reduced...
  • Page 9 - 8 - No. SJ2000-OMM0001-C...
  • Page 10 - 9 - No. SJ2000-OMM0001-C...
  • Page 11 - 10 - No. SJ2000-OMM0001-C...
  • Page 12 - 11 - No. SJ2000-OMM0001-C...
  • Page 13 - 12 - No. SJ2000-OMM0001-C...
  • Page 14 - 13 - No. SJ2000-OMM0001-C...
  • Page 15 - 14 - No. SJ2000-OMM0001-C...
  • Page 16 - 15 - No. SJ2000-OMM0001-C...
  • Page 17 - 16 - No. SJ2000-OMM0001-C...
  • Page 18: Valve Construction

    - 17 - No. SJ2000-OMM0001-C...
  • Page 19 SJ1000/2000/3000/4000 series Specific Product Precautions 1 Be sure to read this before handling. 。 Manual Override Switch Operation When you operate the D type with a screw driver, turn it gently using a precision screwdriver. [Torque: under 0.05 N·m] When you lock the manual override of the D type, be sure to push it before For manual override operation, move the manual override switch to a turning.
  • Page 20 SJ1000/2000/3000/4000 series Specific Product Precautions 2 Be sure to read this before handling. 。 Exhaust Restriction With power saving circuit Since the SJ series is a type in which the pilot valve exhaust joins ■With power saving circuit the main valve exhaust inside the valve, use caution, so that the Compared to the standard products, power consumption is piping from the exhaust port is not restricted.
  • Page 21 SJ1000/2000/3000/4000 series Specific Product Precautions 3 Be sure to read this before handling. 。 Working Principle Light Indication With the circuit of page 19, the current consumption, when holding, is reduced to save energy. Please refer to the electric wave form data below. When equipped with light/surge voltage suppressor, the light window turns orange when solenoid a is energized,...
  • Page 22 However, elbow type and inch size are not available for the SJ4000 series. Note 7) The SJ4000 series one-touch fittings are available only in millimeter sizes (straight type). - 21 -...
  • Page 23 SJ1000/2000/3000/4000 series Specific Product Precautions 5 Be sure to read this before handling. 。 One-touch Fittings Other Tube Brands The pitch of the SJ series piping ports (A, B etc.) has been set 1. When using other than SMC brand tube, confirm that the assuming the use of KJ series One-touch fittings.Therefore, when following specifications are satisfied with respect to the using fittings with an M3 or M5 port block assembly, there may be...
  • Page 24 SJ1000/2000/3000/4000 series Specific Product Precautions 6 Be sure to read this before handling. How to Use Plug Connector Connector Assembly Part No. 3. Lead wires with sockets attachment/detachment • Attachment Insert the sockets into the square holes of the connector (with A, B, C, and N indication), and continue to push the sockets all the way in until the lock by hooking into the seats in the connector.
  • Page 25: Specific Product Precautions 7

    SJ1000/2000/3000/4000 series Specific Product Precautions 7 Be sure to read this before handling. Connector Assembly Part No. Wiring Instructions for Connector Assembly (for Junction Common) (for Junction Common) If only connector assembly (for junction common) is ordered, please wire according to the instructions in the diagram below.
  • Page 26: Trouble Shooting

    TROUBLE SHOOTING valve non-conformance, take Trouble following countermeasures referring to Possible cause Countermeasures trouble. ・Fall of power supply voltage. ・Regulate voltage, so that the voltage at the time of the operation becomes specifications range. ・Faulty wiring. ・Re-wire correctly. Pilot valve is ・...
  • Page 27 Revision history CRENEWAL 2023.6 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 https://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. ©...

This manual is also suitable for:

Sj2000 seriesSj3000 seriesSj1000 series

Table of Contents