Specific Product Precautions 1

Be sure to read before handling.
Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port
Solenoid Valve Precautions.

Manual Override

Warning
The manual override is used for switching the main
valve.
Push type (Tool required)
Push down on the manual override button with a small screwdriver
until it stops.
Plug-in
Bore ø 3.2
How to Attach and Detach a Connector
<Plug lead type only>
To attach a connector, hold the lever and connector unit between
your fingers and insert straight onto the pins of the solenoid valve
so that the lever's pawl is pushed into the groove and locks.
To detach a connector, remove the pawl from the groove by
pushing the lever downward with your thumb, and pull the con-
nector straight out.
Lever
Connector
Lever pawl
Groove
Cover
Note) In order not to damage the connector and cover, do not pull the lead wire
excessively (with a force of 10 N or more).
S0700
Plug lead
Bore ø 3.2
Mounting of Valves
Caution
Tighten the bolts firmly to stop the gasket from com-
ing away from the valve using the appropriate torque
as shown on the following table.
Proper torque N m
0.17 to 0.23
Plug-in
Plug lead
SJ
SY
SV
Mounting screw (M2)
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
Mounting screw (M2)
671

Advertisement

Table of Contents
loading

This manual is also suitable for:

S0710S0720S07a0S07b0S07c0S0715 ... Show all

Table of Contents