7 mm width compact pilot type 5 port solenoid valve
Hide thumbs Also See for S0700 Series:
Table of Contents

Advertisement

S0700
S
Kit (Serial Transmission)
Stations
Symbol
Stations
01
1 station
16
Note)
16 stations
Note) The maximum number of stations will be dif-
ferent depending on the wiring specification.
Cylinder port size
Symbol
Port size
C2
With one-touch fitting for ø2
C3
With one-touch fitting for ø3.2
C4
With one-touch fitting for ø4
CM
Mixed size/with port plug
N1
With one-touch fitting for ø1/8"
N3
With one-touch fitting for ø5/32"
NM
Mixed size/with port plug
Note) Specify "Mixed size/with port plug" in the manifold
specification sheet.
Kit name
Kit name
Decentralized serial wiring
S kit
serial transmission
Note 1) The maximum number of stations is determined by the total number of solenoids.
For mixed single and double wirings, enter "-K" to the order code options.
Note 2) For SI unit part number, refer to page 655.
Type of actuation
Single type
Number of solenoids
1
SI unit COM.
SI unit COM.
DeviceNet
Nil
+COM.
N
–COM.
Note) Without SI unit (SD0), the symbol is nil.
How to Order Valves
Type of actuation
Specification
Symbol
1
2 position single
2
2 position double
4 position dual 3 port type (N.C. + N.C.)
A
[Exhaust center]
4 position dual 3 port type (N.O. + N.O.)
B
[Pressure center]
C
4 position dual 3 port type (N.C. + N.O.)
Note) For JIS symbol, refer to page 616.
Base mounted plug-in
618
EX500 Gateway System Serial Transmission System
How to Order Manifold
SS0750
08 C4
Metric
Note)
Inch
Note)
Symbol
SD0
Without serial unit
SDA2
DeviceNet, PROFIBUS DP, CC-Link, EtherNet/IP
Double, Dual 3 port type
2
EX500
PROFIBUS DP
CC-Link
S07 1 0
Function
Symbol
Nil
R
Note) Not compatible with dual 3 port valves.
SDA2
Option
Symbol
Nil
None
B
Note 2)
With back pressure check valve (all stations)
D
With DIN rail (Rail length: Standard)
D0
Without DIN rail (with bracket)
D „
Note 3)
With DIN rail Designated length („: station)
Note 4)
K
Special wiring specification (Except double wiring)
N
With name plate
R
Note 5)
External pilot
S
Built-in silencer
Note 1) When two or more options are specified, indicate them alphabetically.
Example) -BRS
Note 2) When installing a back pressure check valve on the required station, enter
the part number and specify the station position in the manifold specification
sheet.
Note 3) The available number of stations is larger than the number of manifold
stations.
Note 4) Indicate the wiring specification for mixed single and double wirings.
Note 5) For details, refer to page 648.
∗ For manifold optional parts, refer to pages 648 to 652.
∗ For manifold exploded view, refer to page 654.
Specification
Refer to pages 1680 to 1694 for the details of EX500 gateway system
serial transmission system.
EtherNet/IP
5
Voltage: 24 VDC
Specification
Standard
Note)
External pilot
B
Stations
Max. number of
stations for special
Standard station
wiring specification
1 to 8 stations
16 stations
How to Order Manifold Assembly
Specify the part numbers for valves and
options together beneath the manifold base
part number.
<Example>
Serial transmission kit
SS0750-08C4SDA2 ·····
1 set – Manifold base part no.
∗ S0710-5 ····················
3 sets – Valve part no. (Stations 1 to 3)
∗ S0720-5 ····················
2 sets – Valve part no. (Stations 4 to 5)
∗ S07A0-5 ···················
2 sets – Valve part no. (Stations 6 to 7)
∗ SS0700-10A-1 ··········
1 set – Blanking plate part no. (Station 8)
Write sequentially from the
1st station on the D side.
Prefix the asterisk to
When part nos. written
the part nos. of the
collectively are complicated,
solenoid valve, etc.
specified by using the
manifold specification sheet.
Max. number of
solenoids
16