SMC Networks S0700 Series Manual page 48

7 mm width compact pilot type 5 port solenoid valve
Hide thumbs Also See for S0700 Series:
Table of Contents

Advertisement

S0700
Series
How to Add Manifold Stations (Plug-in Type / Lead Wire Connection Type)
What to order
Manifold block assembly (Refer to page 655.)
Steps for adding stations
Loosen hexagon bolts from the end plate at the U side and remove the
end plate.
Connect the tie rod for increasing the station number, open the junction
cover, mount the manifold block assembly and U-side end plate and
tighten them by hexagon bolts.
(Tightening torque: 0.85 to 0.95 N m)
Connect lead wire assemblies included with manifold blocks as follows.
Socket housing
Convex part
Take out the socket housing and connect the black and white lead wires.
The connection layout is common to all kits.
Convex part
656
Tie-rod for station additions
Junction cover
SOL.A
Red
SOL.B
SOL.B
SOL.B
White
Black
Terminal no.
COM.
Red
1A
2 stations
Black
2A
3 stations
White
3A
4 stations
White
4A
5 stations
White
5A
6A
7A
8A
9A
10A
11A
12A
13A
Hexagon socket head screw
Tightening torque: 0.85 to 0.95 N m
U side end plate
Tightening torque: 0.25 to 0.35 N m
Round type terminal
1B
Red
COM.
2B
Black
1 station
SOL.A
3B
Black
3 stations SOL.A
4B
Black
4 stations SOL.A
5B
Black
5 stations SOL.A
6B
Black
6 stations SOL.A
7B
8B
9B
10B
11B
12B
13B

Advertisement

Table of Contents
loading

This manual is also suitable for:

S0710S0720S07a0S07b0S07c0S0715 ... Show all

Table of Contents