Kit name / Cable length
Kit
Symbol
Specification
name
FD0
D-sub connector (25P), without cable
FD1
D-sub connector (25P), with 1.5 m cable
F kit
FD2
D-sub connector (25P), with 3.0 m cable
FD3
D-sub connector (25P), with 5.0 m cable
Note) The maximum number of stations is determined by the total number of solenoids.
For mixed single and double wirings, enter "-K" to the order code options.
Type of actuation
Single type
Number of solenoids
How to Order Valves
Type of actuation
Symbol
Specification
1
2 position single
2
2 position double
4 position dual 3 port type (N.C. + N.C.)
A
[Exhaust center]
4 position dual 3 port type (N.O. + N.O.)
B
[Pressure center]
C
4 position dual 3 port type (N.C. + N.O.)
Note) For JIS symbol, refer to page 616.
Base mounted plug-in
How to Order Manifold
SS0750
Stations
Symbol
Stations
02
2 stations
Note)
24
24 stations
Note) The maximum number of stations
will be different depending on the
wiring specification.
Cylinder port size
Port size
Symbol
C2
With one-touch fitting for ø2
C3
With one-touch fitting for ø3.2
C4
With one-touch fitting for ø4
CM
Mixed size/with port plug
Note)
N1
With one-touch fitting for ø1/8"
N3
With one-touch fitting for ø5/32"
NM
Note)
Mixed size/with port plug
Note) Specify "Mixed size/with port plug" in the manifold
specification sheet.
Standard station
1 to 12 stations
Double, Dual 3 port type
1
2
S07 1 0
Function
Symbol
Nil
R
Note) Not compatible with dual 3 port valves.
08 C4
FD1
Metric
Inch
Max. number of
Max. number of
stations for special
solenoids
wiring specification
24 stations
24
5
Voltage
Specification
Symbol
5
24 VDC
6
12 VDC
Specification
Standard
Note)
External pilot
S0700
Plug-in
B
Option
Symbol
Option
Nil
None
With back pressure check valve
B
Note 2)
(all stations)
D
With DIN rail (Rail length: Standard)
D0
Without DIN rail (with bracket)
With DIN rail Designated length
D „
Note 3)
(„: station)
Special wiring specification (Except
Note 4)
K
double wiring)
N
With name plate
Note 5)
R
External pilot
S
Built-in silencer
Note 1) When two or more options are specified,
indicate them alphabetically. Example) -BRS
Note 2) When installing a back pressure check valve
on the required station, enter the part number
and specify the station position in the manifold
specification sheet.
Note 3) The available number of stations is larger than
the number of manifold stations.
Note 4) Indicate the wiring specification for mixed
single and double wirings.
Note 5) For details, refer to page 648.
∗ For manifold optional parts, refer to pages 648 to
652.
∗ For manifold exploded view, refer to page 654.
How to Order Manifold Assembly
Specify the part numbers for valves and
options together beneath the manifold base
part number.
<Example>
Serial transmission kit
1 set – Manifold base part no.
SS0750-08C4FD1 ······
∗ S0710-5 ···················
3 sets – Valve part no. (Stations 1 to 3)
∗ S0720-5 ···················
2 sets – Valve part no. (Stations 4 to 5)
∗ S07A0-5 ···················
2 sets – Valve part no. (Stations 6 to 7)
∗ SS0700-10A-1 ·········
1 set – Blanking plate part no. (Station 8)
Write sequentially from the
1st station on the D side.
Prefix the asterisk to
When part nos. written
the part nos. of the
collectively are complicated,
solenoid valve, etc.
specified by using the
manifold specification
sheet.
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
625

Advertisement

Table of Contents
loading

This manual is also suitable for:

S0710S0720S07a0S07b0S07c0S0715 ... Show all