SMC Networks S0700 Series Manual page 29

7 mm width compact pilot type 5 port solenoid valve
Hide thumbs Also See for S0700 Series:
Table of Contents

Advertisement

Stations
Symbol
Stations
01
1 station
Note)
20
20 stations
Note) The maximum number of stations will be different
depending on the wiring specification.
Cylinder port size
Symbol
C2
With one-touch fitting for ø2
C3
With one-touch fitting for ø3.2
C4
With one-touch fitting for ø4
CM
Mixed size/with port plug
N1
With one-touch fitting for ø1/8"
N3
With one-touch fitting for ø5/32"
NM
Mixed size/with port plug
Note) Specify "Mixed size/with port plug" in the manifold specification sheet.
Kit name
Kit name
Symbol
Specification
TD0
T kit
Terminal block
Note) The maximum number of stations is determined by the total number of solenoids.
For mixed single and double wirings, enter "-K" to the order code options.
Type of actuation
Single type
Number of solenoids
How to Order Valves
Type of actuation
Symbol
Specification
1
2 position single
2
2 position double
4 position dual 3 port type (N.C. + N.C.)
A
[Exhaust center]
4 position dual 3 port type (N.O. + N.O.)
B
[Pressure center]
C
4 position dual 3 port type (N.C. + N.O.)
Note) For JIS symbol, refer to page 616.
Base mounted plug-in
How to Order Manifold
SS0750
Port size
Metric
Note)
Inch
Note)
Max. number of
stations for special
Standard station
wiring specification
1 to 10 stations
20 stations
Double, Dual 3 port type
1
2
S07 1 0
Function
Symbol
Nil
R
Note) Not compatible with dual 3 port valves.
08 C4
TD0
Option
Symbol
Nil
None
Note 2)
B
With back pressure check valve (all stations)
D
With DIN rail (Rail length: Standard)
D0
Without DIN rail (with bracket)
D „
Note 3)
With DIN rail Designated length („: station)
K
Note 4)
Special wiring specification (Except double wiring)
N
With name plate
Note 5)
R
External pilot
S
Built-in silencer
Note 1) When two or more options are specified, indicate them alphabetically.
Example) -BKN
Note 2) When installing a back pressure check valve on the required station, enter
the part number and specify the station position in the manifold specification
sheet.
Note 3) The available number of stations is larger than the number of manifold
stations.
Note 4) Indicate the wiring specification for mixed single and double wirings.
Note 5) For details, refer to page 648.
∗ For manifold optional parts, refer to pages 648 to 652.
∗ For manifold exploded view, refer to page 654.
Max. number of
solenoids
20
5
Voltage
Specification
Symbol
5
24 VDC
6
12 VDC
Specification
Standard
Note)
External pilot
S0700
Plug-in
B
Option
How to Order Manifold Assembly
Specify the part numbers for valves and
options together beneath the manifold base
part number.
<Example>
Terminal block kit
1 set – Manifold base part no.
SS0750-08C4TD0 ···
∗ S0710-5 ················
3 sets – Valve part no. (Stations 1 to 3)
∗ S0720-5 ················
2 sets – Valve part no. (Stations 4 to 5)
∗ S07A0-5 ···············
2 sets – Valve part no. (Stations 6 to 7)
∗ SS0700-10A-1 ······
1 set – Blanking plate part no. (Station 8)
Write sequentially from the
1st station on the D side.
Prefix the asterisk to
When part nos. written
the part nos. of the
collectively are complicated,
specified by using the
solenoid valve, etc.
manifold specification sheet.
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
637