Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) , and other safety regulations.
Page 4
Safety Instructions Caution The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch.
Page 5
2/3-Port Solenoid Valves Precautions 1 Be sure to read this before handling products. Design/Selection Warning Caution 1. Confirm the specifications. Leakage voltage Products represented in this catalog are designed only for use Take note that the leakage voltage will increase when a in compressed air systems (including vacuum).
2/3-Port Solenoid Valves Precautions 2 Be sure to read this before handling products. Design/Selection Caution Caution 4. Surge voltage intrusion Operation in low temperature conditions Applicable series (non-polar type solenoid valves) Take appropriate measures to avoid the freezing of drainage, moisture, etc., in low temperatures. With non-polar type solenoid valves, at times of sudden interruption of the loading power supply, such as emergency 6.
2/3-Port Solenoid Valves Precautions 3 Be sure to read this before handling products. Wiring Air Supply Caution Warning 1. The solenoid valve is an electrical product. For 1. When extremely dry air is used as the fluid, safety, install an appropriate fuse and circuit degradation of the lubrication properties breaker before use.
2/3-Port Solenoid Valves Precautions 4 Be sure to read this before handling products. Operating Environment Caution 1. Temperature of ambient environment Use the valve within the range of the ambient temperature specification of each valve. In addition, pay attention when using the valve in environments where the temperature changes drastically.
Dimensions 2-port SX91 /Normally closed Base hole dimension SX92 /Universal ±0.05 2 x M2 x 0.4 Thread depth: 6 or more (Lead wire AWG#26) ±5 38.1 +0.05 2 x ø3 (Port hole dimension) (4.5 ±0.05 C0.2 or less +0.05 (2 x ø3 Mounting screw (Included) 2 x ø2.8 M2 x 11...
Troubleshooting Check and take corrective action following the troubleshooting below. Counterm easure Failure phenomenon Cause (Refer to the next page) Operation failure Incorrect wiring The valve does not perform Blown fuse and/or broken lead wire Incorrect contact at the contact and connection Broken wire in the coil.
Countermeasure Countermeasures Connect wires correctly. Replace the part with broken wire. Not to pull the valve lead wire too tightly. Replace the parts or connect wires correctly. Replace the valve. Remove foreign matter in the piping by air blow and replace the valve. Clean the air supply.