Verifying Cross Direction And Machine Direction Head Alignment; Verifying Vertical Direction Head Alignment - Honeywell Precision Platform 4022 Series System Manual

Hide thumbs Also See for Precision Platform 4022 Series:
Table of Contents

Advertisement

System Testing and Verification
WARNING
4.2.7.1.
CAUTION
!
4.2.7.2.
N
:
i
OTE
P/N 6510020208
If the air gap of a sensor containing a radioactive or X ray source is
changed from its original size (for example, from a 0.4 in gap to a
0.5 in gap), regulations require that a radiation survey be
:
performed and documented before the sensor is placed back into
use. This survey must be performed by an individual who is
specifically licensed to perform this operation.
Verifying cross direction and machine direction head
alignment
Whether or not the heads line up in the cross, vertical, and machine
directions is tested by inserting the head alignment pins. If the pins do not
go through both heads with the heads located on both the scanner cable
and drive ends, the heads are not properly lined up. See Subsection 9.6.3
and Subsection 9.6.4 for head alignment procedures.
:
The head alignment pins must be removed before going onsheet.

Verifying vertical direction head alignment

Leave the head alignment pins in the upper head to verify vertical-
direction head alignment or head gap.
Aligning the heads for the vertical direction involves adjusting only the
lower head.
1. Place two spacer bars between the heads (spacer bars are provided
by Honeywell). The size of these spacer bars is determined by the
system's sensor gap.
2. Check the gap between the heads for either of the following
conditions:
• The spacer bars bind
10/4/07
Testing the Precision Platform operation
4-13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents