Spsu-S Power Supply Leds; Environmental Specifications; Acoustic Data; Reliability (Mtbf) - Mellanox Technologies Grid Director 4700 Installation Manual

Table of Contents

Advertisement

Mellanox Grid Director 4700 Installation Manual
3.15.6

sPSU-S Power Supply LEDs

Table 22: sPSU-S Power Supply LEDs

Indication
DC ON (Green)
AC ON (Green)
3.16

Environmental Specifications

Table 23: 4700 Environmental Specifications

Ambient Operating Temperature
Operating Humidity
Operating Altitude
Storage Temperature
Storage Humidity
Storage Altitude
3.17

Acoustic Data

Acoustic noise is reported in accordance with ISO 7779 [ECMA 74] standard.
3.18

Reliability (MTBF)

The Mean Time between Failures (MTBF) for individual switch components is shown in the
following tables. These figures indicate the mean elapsed time until a single component fails
in the module, whether or not that failure impacts the operation of the switch. Note that in
many cases redundant modules can be configured, which dramatically increases the overall
system Mean Time between Critical Failures (MTBCF).
MTBF per 4700 model types:
Model A: The system configuration is a fully populated chassis with 18 line cards, 9 fabric
cards, 3 power supplies, 1 Management Board and 2 fan modules (Horizontal and Vertical
drawers).
Model B: The system configuration is a fully populated chassis with 18 line cards, 9 double
fabric cards, 4 power supplies, 1 Management Board and 2 fan modules (Horizontal and
Vertical drawers).

Table 24: Reliability (MTBF) Specifications

4700 QDR Director
Model A
Model B
Description
ON – Indicates that the DC power source is present.
ON – Indicates that the AC power source is present.
32° to 113°F (0° to 45°C)
15 to 80%, non-condensing
0 to 9843 ft (3000m)
-13° to 158°F (-25° to +70°C)
5 to 90% non-condensing
0 to 15,000 ft (4570m)
FPMH
66.308
75.431
MTBF (Hours)
15,081
13,257
35

Advertisement