12.3

Energy Probe setup

ARM DUI 0482K
ID120712
When first plugging in the Energy Probe on Windows, the LED flashes RED at approximately
one second intervals. This indicates the USB enumeration has failed and that you must install
the driver. To install, use the standard Windows driver installation wizard and, if required, select
the
configuration file. This file is located in
ARM_EnergyProbe.inf
. There is no driver DLL, because Energy Probe uses the built-in USB CDC virtual serial
probe/
port functionality on both Windows and Linux.
To setup on Linux Ubuntu, enter the following command:
sudo apt-get install libudev-dev
On Linux Ubuntu, you must either change the permissions of the
the dialout group for Energy Probe to successfully use the device. To change the permissions
of the
device, use the following command:
tty
chmod 777 tty_location
Note
is the usual location of the
/dev/ttyACM0
As an alternative, you can add yourself to the same group as the tty device. To do so, enter the
following command:
usermod -a -G Group_Name User_Name
Note
is the usual name of the group for the
dialout
When you have installed the driver and it is operating correctly, the LED remains green.
Attaching a probe backwards to Energy Probe or the target causes the LED to turn red.
Backwards connections do not damage your target or Energy Probe but this kind of connection
does not provide useful data. Disconnect all Energy Probe probes and wait until the LED
changes to green, then reattach one by one and make sure to reverse the polarity on any probe
that results in the LED changing to red. When you have attached the Energy Probe correctly, the
LED remains green.
Note
In case of low consumption, it is possible that the LED remains red even if the connection is
right. This might happen if the target device is idle.
Caution
The Energy Probe requires a common ground between the probe and the target. Take special
care when first attaching the ground pin and the probes. The following symptoms are an
indication that you have attached to the wrong testpoint:
the LEDs on your target suddenly turn off
the Energy Probe LED turns off
you hear a buzzing sound from the board or the power supply.
Quickly remove the probe from the target and check you have not damaged your target.
Copyright © 2010-2012 ARM. All rights reserved.
Non-Confidential
install_directory/sw/energy
tty
device.
tty
device.
tty
Using the Energy Probe
device or add yourself to
12-5