10.4.2
Log view table headers
10.4.3
Log view totals panel
ARM DUI 0482K
ID120712
Here is a list of all of the column headers available in the Log view:
When
This value, given in seconds, tells you when message was generated during the
captured execution. All messages appear in the Log view in chronological order.
Delta
The difference in time between when this message and the one previous to it were
generated. Filtering affects the values in this column. If your searches narrow this
list down, the delta values reflect only the filtered messages.
Message
The contents of the message generated by
contains an image, a camera icon appears in the Message column. Select a row
with a camera icon to see the image.
Core
The core that generated the message.
Where
The process and thread that generated the message.
The totals panel provides additional information when you select multiple messages in the Log
view.
Log Entries The total number of messages you have selected in the Log view.
Delta
The total difference in time between the function called first and the function
called last amongst the selected functions. Use the totals panel to easily see the
time gap between two messages by clicking on one and holding Ctrl and clicking
on a second. The value in the Totals Panel Delta field updates to show you the
time difference between the two selected messages.
Copyright © 2010-2012 ARM. All rights reserved.
Non-Confidential
Annotate and the Log View
. If an annotation message
ANNOTATE
Figure 10-6 Visual annotation in the Log view