4-7. Replacing the Guide Roller Assembly

Tools
. Torque wrench (For 60 kgf.cm)
. Torque driver bit (For M4)
. 35G height gauge
Removal
1. Removing the FTP panel
(Refer to section 2-7-4.)
2. Removing the guide roller assembly
Remove the three screws, and install the guide
roller assembly.
Installation
3. Installing the guide roller assembly
Install the guide roller assembly using the three
screws.
4. Adjusting the guide roller height
(1) Loosen the fixing screw of the guide roller.
(2) Rotate the bearing holder.
(3) Align the lower flange of the roller guide and
the 35G height gauge, and tighten the fixing
screw.
5. Installing the FTP panel
(Refer to section 2-7-4.)
FVS-1000 MMP1
GR1
GR2
GR5
GR3
GR4
Guide roller assembly
Screws 4 x 10
Set screw
Roller guide 35/16
4-7. Replacing the Guide Roller Assembly
GR11
GR10
GR9
GR6
GR8
GR7
Bearing retainer
Face each oter
35G hight gauge