Installing
c
Be careful not to damage the glass surface of the lamp or
not to make it dirty.
8. Connect the connectors of the new lamp with the
terminals of the lamp house in the direction of arrow.
Lamp
Terminals
9. Install the removed parts in the reverse order of this
procedure.
10. Confirm that when turning on the AC power supply
and turning on the system, the lamp lights and the
message recommending the lamp replacement is not
displayed on the liquid crystal panel of the control
panel.
FVS-1000 MMP1
Lamp house
Connectors
3-4. Replacement of Periodic Replacement Part
Before scrapping the used lamp
Nip the chip off at the rear side of the lamp with nippers
etc., then make V shaped cutting on it with turning nippers
in the direction of arrow until you hear the sound of gas's
going out of the lamp. Be sure to let gas out of the lamp
before scrapping it.
c
When cutting, cover the lamp with a towel etc. not to
scatter the cut pieces of the chip off.
V shaped cut
Chip off
Used lamp
Chip off
Nippers
3-15