3-4. Replacement of Periodic
Replacement Part

3-4-1. Replacing Lamp

When the message of recommending the lamp replacement
is displayed on the liquid crystal panel of the control panel
or the lamp does not light, replace the lamp according to
the following procedure.
c
Air-cool the lamp before replacing it.
The lamp is still heated immediately after turning the
power off, so there is a danger of causing burns with
touching it. When replacing the lamp, turn off the power,
wait for 5 minutes, confirm that the lamp power indicator
stops flashing, turn off the AC power supply which
supplies the power to the FVS-1000, wait for about twenty
minutes until the lamp is air-cooled, then replace the lamp.
w
Observe the following when installing or replacing the
lamp. If not the lamp can burst and may result in injury.
. Do not hit the lamp against something, apply the exces-
sive pressure to it or hurt it.
. Do not give a vibration or shock to the lamp.
. Do not touch the glass ball and reflecting mirror of the
lamp with bare hands.
. Do not use the not-specified lamp.
FVS-1000 MMP1
http://getMANUAL.com
Removing
1. Turn off the AC power supply which supplies the
power to the FVS-1000.
n
To prevent an electric shock, be sure to turn off the power
of the AC power supply which supplied the power to the
FVS-1000 before removing.
2. Remove the gate base (35) assembly.
(Refer to item 3-2-1.)
Gate base (35)
assembly
3. Loosen the four falling-proof screws.
Screws

3-4. Replacement of Periodic Replacement Part

Fixing screws
Screws