2-11. Function of Switches/LEDs on the Board
Ref.No.
Address
Name
S1701
(E-4)
TSG signal selector
S1501
(E-1)
*1: When this bit is OFF, All board status refer to system_bus (HIB) and bit2 to 8 are disabled.
*2: When this bit is ON, Wipe & Mix goes to OFF and Image Enhancer is bypassed.
Other board status conform to bit2 to bit8 and parameters from system_bus (HIB) is ignored.
Thus, control from local control panel or REMOTE is NOT available.
Then, bit2 and bit3 must be set to present system.
2-48
Function
TSG signal select
(When S1700-8 is ON, V or H signals)
0 : Vertical 100% color bars
1 : V sweep for Progressive (Y/Cb/Cr)
2 : V sweep for Interlace (Y/Cb/Cr)
3 : V ramp (Y/Cb/Cr)
4 : Vertical 75% color bars
5 : V sweep for Progressive
(G/B/R : monochrome)
6 : V sweep for Interlace
(G/B/R : monochrome)
7 : V ramp (G/B/R : monochrome)
8 : Horizontal 100% color bars
9 : H sweep 8:8:8/12M (Y/Cb/Cr)
A : H sweep 4:4:4/ 6M (Y/Cb/Cr)
B : H ramp & 5 steps (Y/Cb/Cr)
C : Horizontal 75% color bars
D : H sweep 8:8:8/12M (G/B/R : monochrome)
E : H sweep 4:4:4/ 6M (G/B/R : monochrome)
F : H ramp & 5 steps (G/B/R : monochrome)
(When S1700-8 is OFF, Fixed (flat field) signals)
0, 8 : Black
1, 9 : Pathlogical
(SDI check field for Cable Equalizer)
2, A : Pathlogical
(SDI check field for PLL, D1 style )
3, B : Pathlogical
(SDI check field for PLL, Digi-Beta style)
4, C : 100% White
5, D : 100% Green
6, E : 100% Blue
7, F : 100% Red
Factory use only
Factory setting
8
All bits ON