Omron CJ Series Operation Manual page 222

Machine automation controller
Hide thumbs Also See for CJ Series:
Table of Contents

Advertisement

6 Message Communications
End code
1004 hex
1005 hex
110B hex
2211 hex
2609 hex
Number of Bytes Received (Response)
The number of bytes of data received from the destination (remote node) node address onwards is
returned.
Destination (Remote Node) Node Address (Response)
The remote node address of the response source is returned.
Error Code (Response)
An error code that is defined by the CompoNet Network is returned.
For details, refer to the following table of error codes.
Error Codes
Error code
0x02FF hex
0x08FF hex
0x09FF hex
0x0BFF hex
0x0CFF hex
0x0EFF hex
0x10FF hex
0x11FF hex
0x13FF hex
0x14FF hex
0x15FF hex
0x16FF hex
0x19FF hex
0x1F@@ hex
0x20FF hex
0x28FF hex
Description
• SEND EXPLICIT MESSAGE command sends an explicit message defined by CompoNet to a
Slave Unit by another manufacturer and receives a response.
• For the SEND EXPLICIT MESSAGE command, specify the CompoNet Master Unit at the local
node as the destination in the control code in the SendCmd instruction, and specify the node
address of the actual destination for the destination node address in the SEND EXPLICIT MES-
SAGE command. Always specify the Master Unit at the local node in the control code of the Send-
Cmd instruction. If the Master Unit at any other node is specified, an error will occur.
6-8
The command format is not suitable.
There is a header error. (The destination address setting is illegal.)
The response exceeded the maximum response length.
The Unit is busy. (The memory required for internal transmission processing
cannot be reserved.)
The required settings have not been made.
A required resource was not available.
A requested service is not supported.
Attribute data is illegal.
The specified object was already in the requested state.
The requested service cannot be executed for the specified object.
An unchangeable attribute was specified.
The requested service cannot be executed for the specified device.
The response data is too long to be processed.
There is insufficient data provided for processing.
The attribute is undefined.
Invalid data is included.
The object is not implemented.
The save operation failed.
A header error occurred. (Detailed error information is stored in @@.)
There is an error in the parameters.
A class, instance, or attribute that is not implemented was specified for the member
ID of the requested service.
CJ-series CompoNet Master Unit Operation Manual for NJ-series CPU Unit (Cat. No. W493)